Routine
(,
Number
Description
Error Code
Meaning
TR101
Determines if both tape tracks return interrupts and if the
0982
Status Error - BOT status
sync byte (hex E7) can be read from both tracks.
active once, but not active
now.
0983
Read Data Error - No
interrupt (read clock) detected
(
,.
from either tape track.
0985
Read Data Error - No
interrupt (read clock) detected
from tape track 0 (format
track).
C~
0986
Read Data Error - No
interrupt (read clock) detected
from tape track 1 (data
track).
0987
Read Data Error - No sync
byte (hex E7) detected on
tape track 0 (format track).
0988
Read Data Error - No sync
byte (hex E7) detected on
tape track 1 (data track).
0989
Read Data Error - No sync
byte (hex E7) on either tape
l(
track.
TR0312
Cartridge in place status (10) should not be present.
0912
Bad sense bit found.
TR0315
File protect status (02) should be present.
0915
Bad sense bit found.
TR0318
LED on status (04) should be present.
0918
Bad sense bit found.
TR0321
BOT status (01) should not be present; that is, sense bit (01) 0921
Bad sense bit found.
should be on.
TR0324
EOT status (SO) should not be present.
0924
Bad sense bit found.
TR0327
Erase active (08) status should not be present.
0927
Bad sense bit found.
TR0330
Erase active (08) status for track 0 (format track) should be
0930
Bad sense bit found.
present.
(.
Note: This test leaves the erase coil on.