Twisted Pair Recommendations for DTP Communication
Use the following pin configurations for both ends of the shielded twisted pair cables.
12345678
TP Wires
Figure 9.
ATTENTION:
Supported Cables
The distribution amplifiers are compatible with shielded twisted pair cable (F/UTP, SF/UTP,
and S/FTP).
Cable Recommendations
Extron recommends using the following practices to achieve full transmission distances and
reduce transmission errors.
•
•
•
•
Pins:
TIA/EIA T
568 B
Pin
Wire color
1
White-orange
2
Orange
3
White-green
4
Blue
5
White-blue
Green
6
7
White-brown
8
Brown
TP Cable Termination
•
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or
STP201 cable to link the device with DTP transmitters or receivers.
•
N'utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF
d'Extron ou le câble STP201 pour relier le appareil avec les émetteurs ou les
récepteurs DTP.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000
•
XTP DTP 24P/1000 Plenum 1000' (305 m) spool
•
XTP DTP 24 Plug
•
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points
are required, use shielded couplers and punch down connectors.
NOTE: When using shielded twisted pair cable in bundles or conduits, consider the
following:
•
Do not exceed 40% fill capacity in conduits.
•
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
•
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
•
Separate twisted pair cables from AC power cables.
DTP HDMI 4K D Series Transmitter and Receiver • Installation and Operation
Non-Plenum 1000' (305 m) spool
Package of 10
22-236-03
22-235-03
101-005-02
10