• The thermal and mechanical resistance of the conductor used shall correspond to the environment it runs through. • The temperature sensors are of PT1000 type, with resistance of 1kΩ at 0 °C, 3850 ppm / °C. • Sensors shall be always connected. REGULUS - Controller UR1 A-DT - www.regulus.eu │...
Page 3
15 K, at the clockwise end stop, the difference is 8 K. The pump is switched off as soon as the temperature difference between the sensors drops below 4 K. REGULUS - Controller UR1 A-DT - www.regulus.eu │...
Page 4
WARRANTY CERTIFICATE UR1 A-DT Analog Differential Controller THE SELLER GRANTS THE BUYER (CONSUMER) A GUARANTEE PERIOD OF 24 MONTHS WARRANTY CONDITIONS When claiming warranty, this Warranty Certificate must be submitted together with the purchase receipt. The warranty is valid only when the technical conditions set by the Manufacturer, installation manual and instructions in the documentation and on the product itself are maintained.