6. Troubleshooting
SC
Pattern
29500
D
SC
Pattern
49002
D
SC
Pattern
52000
D
260
Error Name / Detection Criteria / Major Cause / Solution
Air release error
-
Air purge detection switch error
Air release lever error
1. Turn the main power switch off and then back on.
2. Remove the foreign object.
3. Replace the horizontal encoder strip.
4. Replace the defective parts (Air purge detection switch or Air purge unit).
5. Replace the machine if the SC cannot be repaired even after executing
steps 1 to 4.
Error Name / Detection Criteria / Major Cause / Solution
The right ink sump is full.
-
-
1. Turn the main power switch off and then back on.
2. Replace the right ink sump.
Error Name / Detection Criteria / Major Cause / Solution
Vertical motor error
-
-
1. Turn the main power switch off and then back on.