The ZMOD4410 Evaluation Kit (EVK) is designed for evaluating
IDT's ZMOD4410 Gas Sensor Module for TVOC. The total volatile
organic compounds (TVOC) measurement is one of the indicators
for indoor air quality (IAQ). In addition, a measurement mode is
provided to trigger an external device (e.g., fan, ventilation) based
on the air quality change.
The ZMOD4410 Evaluation Software allows Windows
operating systems to communicate with the ZMOD4410 EVK via a
USB connection on the user's computer, which functions as a
master. The software and additional related documentation is
available on the IDT website.
The EVK's Communication Board (HiCom) handles the interface
between the user's computer and the ZMOD4410 module mounted
on the ZMOD4410 Sensor Board (Daughter Board). Note: Only one
Communication Board with one Sensor Board can be connected to
the computer at a time.
The ZMOD4410 Evaluation Kit uses an FTDI controller on the
Communication Board to handle the USB protocol, translate
communications, and synchronize communications with the I2C
interface. The Sensor Board includes a decoupling capacitor.
The Communication Board has devices mounted on both sides.
The components on the top side generate a stable supply voltage.
A potentiometer can be used to adjust the internal supply voltage
in the typical range from 1.7V to 3.6V. Alternatively, the user's
external supply voltage can be used. The intensity of the adjacent
LED is proportional to the supply voltage.
© 2019 Integrated Device Technology, Inc.
ZMOD4410 Evaluation Kit User Manual
Features
User-friendly EVK expedites configuration and evaluation of
the ZMOD4410 Gas Sensor
Operates with IDT provided software; either with executable
ZMOD4410 GUI or alternatively with firmware programming
examples for Windows and Linux
The modular design of the EVK allows simple connection of
-based
®
Sensor Boards for different gas sensor derivatives and easy
integration with other sensor products via the I2C interface
The required ZMOD4410 Evaluation Software is available for
download on the IDT website, which also provides background
information on TVOC, gas sensing, and sensor programming.
Supports different methods of operation, including Low Power
Additional pins to measure power consumption, supply
voltage, and GPIO trigger for external device
The bill of materials (BOM) and schematics for the ZMOD4410
Communication Board and Sensor Board are provided at
www.IDT.com/ZMOD4410-EVK.
ZMOD4410-EVK Contents
ZMOD4410 HiCom Communication Board
ZMOD4410 Sensor Board with ZMOD4410 Gas Sensor
Module
0.5m Type-B USB to Micro-USB Cable
ZMOD4410 Evaluation Kit
1
April 3, 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZMOD4410 and is the answer not in the manual?

Questions and answers

Summary of Contents for IDT ZMOD4410

  • Page 1 The ZMOD4410 Evaluation Kit (EVK) is designed for evaluating User-friendly EVK expedites configuration and evaluation of  IDT’s ZMOD4410 Gas Sensor Module for TVOC. The total volatile the ZMOD4410 Gas Sensor organic compounds (TVOC) measurement is one of the indicators Operates with IDT provided software;...
  • Page 2: Table Of Contents

    ZMOD4410 Evaluation Kit User Manual Important Notes Disclaimer Integrated Device Technology, Inc. and its affiliated companies (herein referred to as “IDT”) shall not be liable for any damages arising out of defects resulting from delivered hardware or software (ii) non-observance of instructions contained in this manual and in any other documentation provided to user, or (iii) misuse, abuse, use under abnormal conditions, or alteration by anyone other than IDT.
  • Page 3 Figure 1. Initial Display after Installation of the ZMOD4410 Evaluation Software ....................5 Figure 2. Jumper Settings and Connectors on the Top Side of the ZMOD4410 Communication Board ............6 Figure 3. Jumper Settings, Connections, and Test Points on the Communication Board for the Internal or External Supply Voltage ....7 Figure 4.
  • Page 4: Setup

    ZMOD4410 Evaluation Kit User Manual 1. Setup First Startup To set-up and operate the ZMOD4410 Evaluation Kit (EVK) with the ZMOD4410, refer to the ZMOD4410 EVK Quick Start Guide document included in the kit. 1.2 Required or Recommended User Equipment By default, the internal supply voltage for powering the Sensor Board is generated from the USB voltage supplied by the user’s computer via...
  • Page 5: Evk Hardware Connections And Initial Power-Up

    To set up the EVK hardware before using the software, complete the following procedure: 1. Refer to Figure 2, Figure 3, and Table 1 to determine the correct jumper settings for the ZMOD4410 Communication Board depending on whether an external supply or the internal voltage supply on the board is used.
  • Page 6: Figure 2. Jumper Settings And Connectors On The Top Side Of The Zmod4410 Communication Board

    This connector can be used to connect the ZMOD4410 in different configurations or to measure header the communication lines and voltages on the ZMOD4410 Sensor Board. AD5 is a GPIO pin that can be controlled via the software in the “Odor” measurement mode.
  • Page 7: Figure 3. Jumper Settings, Connections, And Test Points On The Communication Board For The Internal Or External Supply Voltage

    ZMOD4410 Evaluation Kit User Manual Figure 3. Jumper Settings, Connections, and Test Points on the Communication Board for the Internal or External Supply Voltage © 2019 Integrated Device Technology, Inc. April 3, 2019...
  • Page 8: Usage Guide

    “Analysis” (section 2.1.2)  To select a tab, clicking on the name in the main screen. When the ZMOD4410 Evaluation Software is executed and the operation mode has been selected, it shows the “Measurement” tab by default (see Figure 4).
  • Page 9: Software Modes

    2.1.1 “Measurement” Tab Click on the “Measurement” tab to display the measurement options. On this tab, the user can see the properties of the ZMOD4410’s gas measurements, which includes setting the temperature in °C and changing the sample time in seconds used during the gas measurements.
  • Page 10: Figure 5. "Analysis" Tab For Measurement Mode "Standard Operation" And "Low Power Operation

    ZMOD4410 Evaluation Kit User Manual Figure 5. “Analysis” Tab for Measurement Mode “Standard Operation” and “Low Power Operation” For Odor Operation Click on the tab to display the “Analysis” tab (see Figure 6). The “Analysis” tab shows two plots: Algorithmic output signal with indication on trigger activation times (AD5 of connector K3) ...
  • Page 11: Figure 6. "Analysis" Tab For Measurement Mode "Odor

    The “Analysis” tab can be used to see the active measurement data and to load previously acquired measurement result files by using the “load data file” button. For this usage, it is not necessary to connect the ZMOD4410 Evaluation Kit hardware. The “Analysis” tab supports data files with data from multiple sensors if the loaded CSV file has the required format.
  • Page 12: Table 2. Analysis Tab User Options

    The “load data file” button will open a file selection dialog. This function can be used to display and analyze data from a measurement file acquired earlier. The data file must have the same structure as the measurement file created by the ZMOD4410 Evaluation Software. “Data source”...
  • Page 13: Schematics

    ZMOD4410 Evaluation Kit User Manual Schematics Figure 7. Communication Board Schematic – Page 1 © 2019 Integrated Device Technology, Inc. April 3, 2019...
  • Page 14: Figure 8. Communication Board Schematic

    ZMOD4410 Evaluation Kit User Manual Figure 8. Communication Board Schematic – Page 2 © 2019 Integrated Device Technology, Inc. April 3, 2019...
  • Page 15: Figure 9. Sensor Board Schematic

    ZMOD4410 Evaluation Kit User Manual Figure 9. Sensor Board Schematic © 2019 Integrated Device Technology, Inc. April 3, 2019...
  • Page 16: Bill Of Materials (Bom)

    ZMOD4410 Evaluation Kit User Manual 4. Bill of Materials (BOM) Table 3. Communication Board BOM Name Value Package 10µF/16V 0805 100nF 0603 10nF 0805 100nF 0603 100nF 0603 10µF/16V 0805 10µF/16V 0805 10µF/16V 0805 100nF 0603 100nF 0603 100nF 0603...
  • Page 17 ZMOD4410 Evaluation Kit User Manual Name Value Package LP38692-adj SOT-223-5 93LC46B SOT23-6 FT2232HL LQFP64 SN74LVC1T45 SOT23-6 SN74LVC2T45DCT SSOP8_0,65 I_meas 2X02 Select 1X03 K2X4 2X04-90 K2X7 LH-14 V_EXT 1X02 10µH 1210 10µH 1210 10µH 1210 Modul1 Honeywell480-3652-1-ND DIL8 SMD SOCKEL 12.00MHz QUARZ-ABM3 1kΩ...
  • Page 18: Board Layout

    ZMOD4410 Evaluation Kit User Manual Table 4. Sensor Board BOM Designator Quantity Manufacturer Manufacturer Part Number Taiyo Yuden LMK105BJ104KV-F ZMOD4410 Sullins SFH11-PBPC-D07-ST-BK 5. Board Layout Figure 10. HiCom Communication Board Layout – Top Layer Figure 11. HiCom Communication Board Layout – Bottom Layer ©...
  • Page 19: Figure 12. Sensor Board Layout - Top Layer

    ZMOD4410 Evaluation Kit User Manual Figure 12. Sensor Board Layout – Top Layer Figure 13. Sensor Board Layout – Bottom Layer © 2019 Integrated Device Technology, Inc. April 3, 2019...
  • Page 20: Ordering Information

    The information contained herein is provided without representation or warranty of a ny kind, whether express or implied, including, but not limited to, the suitability of IDT's products for any particular purpose, an implied warranty of merchantability, or non -infringement of the intellectual property rights of others. This document is presented only as a guide and does not convey any license under intellectual property rights of IDT or any third parties.

Table of Contents