IDT ZMOD4510-EVK User Manual

IDT ZMOD4510-EVK User Manual

Evaluation kit

Advertisement

Quick Links

Description
The ZMOD4510 Evaluation Kit (EVK) is designed for evaluating
IDT's ZMOD4510 Gas Sensor Module for Total Outdoor Air Quality
(OAQ). The sensor module is optimized for the detection of trace
atmospheric gases, including nitrogen oxides (NOx) and ozone
(O
) and reporting an Air Quality Index (AQI) based on the standard
3
of the US Environmental Protection Agency (EPA).
IDT's Gas Sensor Evaluation Software allows Windows
operating systems to communicate with the ZMOD4510 EVK via a
USB connection on the user's computer, which functions as a
master. The software and additional related documentation is
available on the IDT website.
The EVK's Communication Board (HiCom) handles the interface
between the user's computer and the ZMOD4510 module mounted
on the ZMOD4510 Sensor Board (i.e., daughter board). Note: Only
one Communication Board with one Sensor Board can be
connected to the computer at a time.
The ZMOD4510 Evaluation Kit uses an FTDI controller on the
Communication Board to handle the USB protocol, translate
communications, and synchronize communications with the I
interface. The Sensor Board includes a decoupling capacitor.
The Communication Board has devices mounted on both sides.
The components on the top side generate a stable supply voltage.
A potentiometer can be used to adjust the internal supply voltage
in the typical range from 1.7V to 3.6V. Alternatively, the user's
external supply voltage can be used. The intensity of the adjacent
LED is proportional to the supply voltage.
ZMOD4510 Evaluation Kit
© 2019 Integrated Device Technology, Inc.
USB Cable to Computer
ZMOD4510 Evaluation Kit User Manual
Features
User-friendly EVK expedites configuration and evaluation of
the ZMOD4510 Total Outdoor Air Quality Sensor
Operates with IDT provided software; either with executable
ZMOD4510 GUI or alternatively with firmware programming
examples for Windows
The modular design of the EVK allows simple connection of
-based
Sensor Boards for different gas sensor derivatives and easy
®
integration with other sensor products via the I
The required Gas Sensor Evaluation Software is available for
free download on the IDT website, which also provides
background information on outdoor air quality and sensor
programming.
Additional pins provided to measure power consumption,
supply voltage, and the GPIO trigger for an external device
The bill of materials (BOM) and schematics for the
ZMOD4510 Communication Board and Sensor Board are
included in this document.
C
ZMOD4510-EVK Contents
2
HiCom Communication Board
Sensor Board with ZMOD4510 Gas Sensor Module
3.0m Type-B USB to Micro-USB Cable
HiCom Communication Board
ZMOD4510
1
and Linux
®
®
ZMOD4510
Sensor Board
August 14, 2019
C interface.
2

Advertisement

Table of Contents
loading

Summary of Contents for IDT ZMOD4510-EVK

  • Page 1 The ZMOD4510 Evaluation Kit (EVK) is designed for evaluating User-friendly EVK expedites configuration and evaluation of  IDT’s ZMOD4510 Gas Sensor Module for Total Outdoor Air Quality the ZMOD4510 Total Outdoor Air Quality Sensor (OAQ). The sensor module is optimized for the detection of trace Operates with IDT provided software;...
  • Page 2: Table Of Contents

    ZMOD4510 Evaluation Kit User Manual Important Notes Disclaimer Integrated Device Technology, Inc. and its affiliated companies (herein referred to as “IDT”) shall not be liable for any damages arising out of defects resulting from delivered hardware or software (ii) non-observance of instructions contained in this manual and in any other documentation provided to the user, or (iii) misuse, abuse, use under abnormal conditions, or alteration by anyone other than IDT.
  • Page 3 ZMOD4510 Evaluation Kit User Manual List of Figures Figure 1. Initial Display after Installation of the Gas Sensor Evaluation Software ....................5 Figure 2. Jumper Settings, LEDs, and Connectors on Top Side of ZMOD4510 Communication Board ............6 Figure 3. Jumper Settings, Connections, and Test Points on Communication Board for the Internal or External Supply Voltage .....7 Figure 4.
  • Page 4: Setup

    Complete the following procedure to download and install the ZMOD4510 Evaluation Software with the kit connected: 1. Download the ZMOD4510 Gas Sensor Evaluation Software zip file at www.IDT.com/ZMOD4510-EVK. 2. Create a folder on the user’s computer for the software (e.g., C:\Program Files (x86)\IDT Software). Extract the contents of the downloaded zip file into this folder.
  • Page 5: Evk Hardware Connections And Initial Power-Up

    The Communication Board provides the additional K3 and Modul1 connectors for the following optional uses as described in Table 1. To make use of any of these options, contact IDT for further instructions (see contact information on last page). Extra measurement options (e.g., current consumption to determine the power requirements of the ZMOD4510) ...
  • Page 6: Figure 2. Jumper Settings, Leds, And Connectors On Top Side Of Zmod4510 Communication Board

    This socket can be used to add external components (e.g., a humidity sensor) to the Modul1 DIL socket Communication Board. For further instructions, contact IDT. © 2019 Integrated Device Technology, Inc. August 14, 2019...
  • Page 7: Figure 3. Jumper Settings, Connections, And Test Points On Communication Board For The Internal Or External Supply Voltage

    ZMOD4510 Evaluation Kit User Manual Figure 3. Jumper Settings, Connections, and Test Points on Communication Board for the Internal or External Supply Voltage V_TGT pin on K3 (Bottom) GND pin on K3 (Bottom) GPIO (AD5) on K3 (Top) V ext – External Negative Supply K5 K2 Jumper: If using the internal supply, set ...
  • Page 8: Usage Guide

    ZMOD4510 Evaluation Kit User Manual 2. Usage Guide When the Gas Sensor Evaluation Software with the ZMOD4510 – Outdoor Air Quality option is started, the initial window is displayed as shown in Figure 4. The initial display consists of three blocks: Measurement Control ...
  • Page 9: Signal Analysis Block

    The lower half of the display provides a visualization of the data. This plot shows the AQI based on the standard of the US Environmental Protection Agency (EPA). For additional information, including application notes, white papers and blogs, visit www.idt.com/ZMOD4510.
  • Page 10: Schematics

    ZMOD4510 Evaluation Kit User Manual Schematics Figure 5. Communication Board Schematic – Page 1 © 2019 Integrated Device Technology, Inc. August 14, 2019...
  • Page 11: Figure 6. Communication Board Schematic

    ZMOD4510 Evaluation Kit User Manual Figure 6. Communication Board Schematic – Page 2 © 2019 Integrated Device Technology, Inc. August 14, 2019...
  • Page 12: Figure 7. Sensor Board Schematic

    ZMOD4510 Evaluation Kit User Manual Figure 7. Sensor Board Schematic © 2019 Integrated Device Technology, Inc. August 14, 2019...
  • Page 13: Bill Of Materials (Bom)

    ZMOD4510 Evaluation Kit User Manual 4. Bill of Materials (BOM) Table 3. Communication Board BOM Position Name Value Package 10µF/16V 0805 100nF 0603 10nF 0805 100nF 0603 100nF 0603 10µF/16V 0805 10µF/16V 0805 10µF/16V 0805 100nF 0603 100nF 0603 100nF 0603 100nF 0603...
  • Page 14 ZMOD4510 Evaluation Kit User Manual Position Name Value Package LP38692-adj SOT-223-5 93LC46B SOT23-6 FT2232HL LQFP64 SN74LVC1T45 SOT23-6 SN74LVC2T45DCT SSOP8_0,65 I_meas 2X02 Select 1X03 K2X4 2X04-90 K2X7 LH-14 V_EXT 1X02 10µH 1210 10µH 1210 10µH 1210 Modul1 Honeywell480-3652-1-ND DIL8 SMD Socket 12.00MHz QUARZ-ABM3 1kΩ...
  • Page 15: Board Layout

    ZMOD4510 Evaluation Kit User Manual Table 4. Sensor Board BOM Designator Quantity Manufacturer Manufacturer Part Number Taiyo Yuden LMK105BJ104KV-F ZMOD4510 Sullins SFH11-PBPC-D07-ST-BK 5. Board Layout Figure 8. HiCom Communication Board Layout – Top Layer Figure 9. HiCom Communication Board Layout – Bottom Layer ©...
  • Page 16: Figure 10. Sensor Board Layout - Top Layer

    ZMOD4510 Evaluation Kit User Manual Figure 10. Sensor Board Layout – Top Layer Figure 11. Sensor Board Layout – Bottom Layer © 2019 Integrated Device Technology, Inc. August 14, 2019...
  • Page 17: Ordering Information

    The information contained herein is provided without representation or warranty of a ny kind, whether express or implied, including, but not limited to, the suitability of IDT's products for any particular purpose, an implied warranty of merchantability, or non -infringement of the intellectual property rights of others. This document is presented only as a guide and does not convey any license under intellectual property rights of IDT or any third parties.

Table of Contents