6

Characteristic of Cooling Operation (in Cool/Auto mode)

Characteristics of Heating Operation (in Heat/Auto mode)

Starting Operation
The air conditioner automatically controls the following operation to
prevent the reduction of heating capacity and space comfort.
Defrost Operation
(Frost removal
operation for the
outdoor unit)

Hot start

13
• When the ON/OFF button is pressed again, the air
conditioner will stop operating and the Operation
lamp will turn off.
* When the air conditioner is stopped while in the
Heating Operation, the fan will continue to
operate for approximately 1 minute to remove
residual heat from the indoor unit.
Note
• To prevent water leakage or system failure, do not turn off the
power immediately. Wait at least 5 minutes for the drain pump to
direction, air blows in the automatically set direction for a period of time
• If the Cooling Operation is used when the room temperature is low,
frost forms on the heat exchanger of the indoor unit.
This can decrease the cooling capacity. In this case, the air conditioner
automatically switches to the Defrost Operation for a while.
used to prevent the discharge of melt water.
• When the outdoor air temperature is high, it takes some time until the
room temperature reaches the set temperature.
• Heating Operation generally requires a longer time to reach the set
temperature compared with Cooling Operation.
It is recommended to start operating in advance by utilizing the timer.
• The air conditioner will automatically go into Defrost Operation to prevent
frost accumulation at the outdoor unit and loss of heating capacity.
• The indoor unit fan will stop, and "
displayed on the remote controller.
• The air conditioner will return to normal operation after approximately 6
to 8 minutes (Max 10 minutes).
• When the air conditioner goes into Heating Operation or Defrost
Operation, the indoor unit fan will stop in order to prevent a cold draft.
(In that case, "
remote controller.)
" (Defrost/Hot start) will be
" (Defrost/Hot start) will be displayed on the