WIRED REMOTE CONTROLLER OPERATION MANUAL BRC1E62 • Thank you for purchasing this product. • This manual describes safety precautions required for the use of the product. Read this manual carefully and be sure you understand the information before using the product.
Safety Precautions – Items to be Strictly Observed – This product is not intended for use by children or infirm persons without supervision. Children should be supervised to ensure that they do not play with the product. Read the safety precautions carefully for the proper use of the product. •...
Page 4
CAUTION • Do not allow children to play with the remote controller. Accidental operation by children may result in health impairment. • Do not disassemble the product. Touching the interior parts may result in electric shocks or a fire. Consult your local dealer for internal inspections and adjustments. •...
Button Location and Descriptions 1. Mode Selector button 11. LCD (with backlight) 4. Up button 5. Down button 6. Right button 7. Left button 9. Operation lamp (Green) 8. ON/OFF button 3. Menu/Enter button 10. Cancel button 2. Airflow Setting button Basic operation (i.e., ON/OFF, Operation Mode, Airflow Rate (Air Volume/Fan Speed), Airflow Direction and Set Temperature) are manipulable directly by the above button.
Page 7
1. Mode Selector button 7. Left button " " • Use to select the operation mode of your • Used to highlight the next items on the preference. (Refer to page 11.) left-hand side. * Available modes vary with the connecting •...
Names and Functions Basic Screen • Basic screen are two types of Standard display screen and Detailed display screen. The Standard display screen is set by default. • To switch to the Detailed display, select the "Detailed" in the Main Menu. (Refer to page 51.) •...
1. Operation Mode • If a number of indoor units are in operation, the message will appear only if none of the • Displays the present operation mode, indoor units is provided with the "Cool", "Heat", "Vent", "Fan", "Dry" or corresponding function, i.e., the message "Auto".
Page 10
10. Centralized Control " " • Displayed if the system is under the management of centralized control equipment (optional accessories) and the operation of the system through the remote controller is prohibited. 11. Changeover Under Control " " (VRV only) •...
Basic Operation (Use of Direct Buttons) How to follow the operation manual Operation button Operation procedure Describes the positions of buttons to be pressed. Explains a button operation procedure. Operation • Display the Main Menu screen. (Refer to Main Menu Operation Quick Start page 27.)
Page 13
• Press ON/OFF button. The Operation lamp (green) will be lit and the system will start operating. • The set temperature will increase by 1°C when " " button is pressed and decrease by Cool Set to 1°C when " " button is pressed. Cool °C * No temperature settings are possible while operating in Fan...
Page 14
<Airflow Direction Setting> Air volume/direction • With Direction selected, set the desired airflow Air volume Direction Position 0 Position 0 Position 1 direction from, Swing Position 2 Position 3 Position 4 Auto using the " " buttons. Return Return Setting Setting Air volume/direction Note...
Page 15
• When the ON/OFF button is pressed again, the air conditioner will stop operating and the Operation lamp will turn off. * When the air conditioner is stopped while in the Heating Operation, the fan will continue to operate for approximately 1 minute to remove residual heat from the indoor unit.
Regarding • The heating capacity will drop with a decrease in outdoor air temperature. outdoor air If the heating effect is insufficient, it is recommended to use another temperature and heating appliance in combination with the air conditioner. (When a combustion appliance is used, ventilate the room regularly.) heating capacity Do not use the combustion appliance in places where the combustion appliance is exposed to the wind from the air conditioner.
Page 17
• To set airflow direction refer to page 12. • When ON/OFF button is pressed again, the air conditioner will stop operating and the Operation lamp will be turned off. Note • To prevent water leakage or system failure, do not turn off the power immediately.
Characteristics of Dry Operation Dry mode repeats the weak cooling operation intermittently to dehumidify the room without dropping the room temperature as much as possible for the prevention of excessive cooling. Setback The Setback function will maintain the room temperature in a specific range during unoccupied periods.
Ventilation Operation When Air Conditioner Interlocked with Heat Reclaim Ventilator Preparation • For equipment protection purposes, turn on the power to the air conditioner at least 6 hours before starting the operation. Operation • Press Mode Selector button several times until Vent mode is selected.
Setting the Cool/Heat Selection Eligibility (VRV only) Refer to "Cool/Heat Selection Eligibility" on page 20 for an explanation of Setting Changes the cool/heat selection eglibility. • Press Mode Selector button on the remote controller that has cool/heat selection eligibility for at least Cool Set to 4 seconds.
Page 21
• Press Mode Selector button on the remote controller that has the cool/heat selection Cool Set to eligibility (the remote controller without the icon Cool °C " ") several times until the desired mode is selected. The display will change to "Fan", "Dry", "Auto", "Cool", "Heat"...
Precautions for Setting Cool/Heat Selection Eligibility • The cool/heat selection eligibility needs to be set for a single remote controller in the following case. (Heat Pump System) (Heat Recovery System) BS (Branch Selector) unit: The BS unit is used for cool or heat mode selection.
Quick Reference of Main Menu Main Menu Items Setting and display items Description Reference page Air Flow Individual setting Used to set an Airflow direction for maximum 4 flaps individually. Direction • In case of Sprit system, maximum 4 units (only if the (unit A, B, C, D) individual airflow...
Setting and display items Description Reference page After you turn on the air conditioner, it will Energy Off Timer automatically turn off in a defined period of Saving time. Options • Possible to set in 10 minutes increments from 30 to 180 minutes. An electricity consumption until now is Electricity displayed.
Setting and display items Description Reference page • The draft prevention function can be en- Configuration Draft prevention (only abled or disabled. if the sensing sensor is installed) Used to set to standard or detailed display Display mode. • Display Standard or detailed display •...
Menu Manipulation Manipulating the Main Menu Screen Display Method for Main Menu Operation • Press Menu/Enter button. Cool Set to Cool °C Basic screen • The Main Menu screen will appear. Main Menu Air Flow Direction Quick Start Ventilation Energy Saving Options Schedule Filter Auto Clean Instructions for manipulating the buttons will...
Individual Airflow Direction Individual Setting Operation • Display the Main Menu screen (Refer to Main Menu page 27). Air Flow Direction Quick Start • Select Air Flow Direction in the Main Menu. • Press Menu/Enter button to display the Air Flow Direction settings screen.
Page 30
• If individual airflow direction is set, the Individual Airflow Direction icon " " is displayed in the Basic Cool Set to screen. Cool °C Basic screen Individual Setting List Operation • Display the Air Flow Direction screen (Refer to Air Flow Direction page 28).
Individual Set All Reset Operation • Display the Air Flow Direction screen (Refer to Air Flow Direction page 28). Individual setting Individual setting List • Press " " buttons to select Individual set all reset Individual set all reset • Press Menu/Enter button. Return Setting •...
Quick Start Off Operation • While Quick Start is displayed on the Basic Main Menu screen, display the Main Menu screen (Refer to Air Flow Direction Quick Start page 27). Ventilation Energy Saving Options Quick Start • Press " " buttons to select Schedule Filter Auto Clean Press Menu/Enter button to return to the Basic...
Ventilation Display Method for Ventilation Screen Operation • Display the Main Menu screen. Main Menu (Refer to page 27.) Air Flow Direction Quick Start Ventilation • Press " " buttons to select Ventilation Energy Saving Options (For models with no ventilation function, Schedule Filter Auto Clean Ventilation...
Energy Saving Options Display Method for Energy Saving Options Screen Operation • Display the Main Menu screen. Main Menu (Refer to page 27.) Air Flow Direction Quick Start • Press " " buttons to Ventilation Energy Saving Options select Energy Saving Options Schedule Filter Auto Clean Press Menu/Enter button to display the Energy...
Page 36
Setpoint Range Setting Operation • Display the Energy Saving Options screen (Refer Energy Saving Options Energy Saving list to page 34). Setpoint range set • Press “ ” buttons to select Setpoint range set Set back condition Sensing Sensor (low) Press Menu/Enter button to display the Setpoint Sensing Sensor (stop) Setpoint Auto Reset...
Page 37
Setback Condition Operation • Display the Energy Saving Options screen (Refer Energy Saving Options Energy Saving list to page 34). Setpoint range set • Press " " buttons to select Set back condition Set back condition Sensing Sensor (low) Press Menu/Enter button to display the Set back Sensing Sensor (stop) Setpoint Auto Reset condition screen.
Page 38
Sensing Sensor (low) This function cannot be used at the time of group control. In case of the simultaneous operation system, the system is controlled by the sensing sensor mounted in the master indoor unit. Operation • Display the Energy Saving Options screen (Refer Energy Saving Options Energy Saving list to page 34).
Page 39
Sensing Sensor (stop) This function cannot be used at the time of group control. In case of the simultaneous operation system, the system is controlled by the sensing sensor mounted in the master indoor unit. Operation • Display the Energy Saving Options screen (Refer Energy Saving Options Energy Saving list to page 34).
Page 40
Setpoint Auto Reset Operation • Display the Energy Saving Options screen (Refer Energy Saving Options Energy Saving list to page 34). Setpoint range set • Press " " buttons to select Set back condition Sensing Sensor (low) Setpoint Auto Reset Sensing Sensor (stop) Setpoint Auto Reset Press Menu/Enter button to display the Setpoint...
Page 41
Off Timer Operation • Display the Energy Saving Options screen. (Refer Energy Saving Options to page 34.) Off Timer Electricity consumption • Press " " buttons to select the Off Timer Press Menu/Enter button to display the Off Timer screen. Return Setting •...
Page 42
Electricity Consumption This item may not be available depend on the connecting model. Operation • Display the Energy Saving Options screen (Refer Energy Saving Options Off Timer to page 34). Electricity consumption • Press " " buttons to select Electricity consumption Press Menu/Enter button to display the Electricity Return Setting...
Schedule Display Method for Schedule Screen The Schedule can not be enabled when a centralized control equipment is connected. Operation • Display the Main Menu screen. Main Menu (Refer to page 27.) Air Flow Direction Quick Start • Press " "...
Page 44
Schedule Nr Set Operation This function can be stored in the schedule of 3 patterns. • Display the Schedule screen. (Refer to Schedule page 42.) Enable/Disable Schedule nr set • Press " " buttons to select Schedule nr set Holidays Settings Press Menu/Enter button to display the Schedule nr set screen.
Page 45
Holidays (The schedule timer will be disabled for days that have been set as holiday.) Operation • Display the Schedule screen. (Refer to Schedule page 42.) Enable/Disable Schedule nr set Holidays • Press " " buttons to select Holidays Settings Press Menu/Enter button to display the Holiday setting screen.
Page 46
Schedule Settings Operation • Display the Schedule screen. (Refer to Schedule page 42.) Enable/Disable Schedule nr set • Press " " buttons to select Settings Holidays Settings Press Menu/Enter button to display the Schedule screen. Return Setting NOTE: The Schedule Settings of the selected schedule number can be changed.
Page 47
• The cooling and heating set temperature for both Schedule nr 1 ON and OFF (Setback) are configured. Time Cool Heat – 6 :00 ON 28°C 21°C "Cool" and "Heat" column: – 8 :00 OFF – – °C – – – :– – – – –...
Page 48
Enabling or disabling the schedule Operation • Display the Schedule screen. Schedule (Refer to page 42.) Enable/Disable Schedule nr set • Press " " buttons to select Enable/Disable Holidays Settings Press Menu/Enter button to display the Enable/ Disable screen. Return Setting Enable Disable...
Filter Auto Clean Operation • Display the Main Menu screen. Main Menu (Refer to page 27.) Air Flow Direction Quick Start • Press " " buttons to select Filter Auto Clean Ventilation Energy Saving Options and press Menu/Enter button. Schedule Filter Auto Clean Setting Return...
Maintenance Information Display Method for Maintenance Information Operation • Display the Main Menu screen. Main Menu (Refer to page 27.) Maintenance Information Configuration • Press " " buttons to select Current Settings Clock & Calender Maintenance Information and press Menu/Enter Language button.
Configuration Display Method for Configuration Screen Operation • Display the Main Menu screen. Main Menu (Refer to page 27.) Maintenance Information Configuration • Press " " buttons to select Configuration Current Settings Clock & Calendar Press Menu/Enter button to display the Language Configuration screen.
Page 52
Display Display Mode Operation • Display the Configuration screen. (Refer to page Configuration 50.) Draft prevention Display Display • Press " " buttons to select Contrast Adjustment Press Menu/Enter button to display the Display screen. Return Setting • Press " "...
Page 53
Setting the detailed display item selection Operation • Display the Display screen. (Refer to page 51.) Display Display Mode Standard • Press " " buttons to select Display Item Display Item None Press Menu/Enter button to display the Display Item screen. Return Setting •...
Page 54
Contrast Adjustment Operation • Display the Configuration screen. (Refer to Configuration page 50.) Draft prevention Display • Press " " buttons to select Contrast Adjustment Contrast Adjustment Press Menu/Enter button to display the Contrast Return Setting Adjustment screen. • On the Contrast Adjustment screen, press " "...
Current Settings Manipulating the Current Settings Operation • Display the Main Menu screen. Main Menu (See page 27.) Maintenance Information Configuration • Press " " buttons to select Current Settings Current Settings Clock & Calendar and press Menu/Enter button. Language Return Setting •...
Clock & Calendar Display Method for Clock & Calendar Screen Operation • Display the Main Menu screen. (Refer to Main Menu page 27.) Maintenance Information Configuration Current Settings • Press " " buttons to select Clock & Calendar Clock & Calendar Language Press Menu/Enter button to display the Clock &...
Page 57
• Select "Day" with " " buttons. Date & Time Year 2013 Change the day with " " buttons. Month 04 Holding down the button causes the number to Thursday 0:00 change continuously. Days of the week change automatically. Return Setting •...
Page 58
12H/24H Clock Operation • Display the Clock & Calendar screen. (Refer to Clock & Calendar page 55.) Date & Time 12H/24H Clock • Press " " buttons to select 12H/24H Clock Press Menu/Enter button to display the 12H/24H Clock screen. Return Setting By default, the time display is set to the...
Language Selectable Languages Operation • Display the Main Menu screen. (Refer Main Menu to page 27.) Maintenance Information Configuration Current Settings • Press " " buttons to select Language Clock & Calendar Language press the Menu/Enter button. Return Setting • Press " "...
Maintenance Reset Filter Indicator Operation • When the time to clean the filter or element has come, one of the following messages will appear on the bottom of the Basic screen. Cool Set to Cool "Time to clean filter" °C "Time to clean filter &...
Caution • Do not wash the remote • Be sure to stop the operation of controller. the air conditioner and turn off Doing so may cause electric the power at the time of maintenance. leakage and result in electric shocks or a fire.
Reference Information Malfunction (Error) code Display Contact Your Dealer in the Following Cases Warning • When the air conditioner is malfunctioning (e.g., giving off a burning odor), stop the air conditioner and turn off the power. Continued operation under such circumstances may result in failure, electric shocks or a fire. Contact your local dealer.
After-sales Service Warning • Do not disassemble, modify, or • Do not relocate or reinstall the repair the remote controller. remote controller by yourself. It may cause electric shocks or a fire. Improper installation may cause electric Consult your local dealer. shocks or a fire.
Need help?
Do you have a question about the BRC1E62 and is the answer not in the manual?
Questions and answers
Can’t get the screen inside the house to turn on
The Daikin BRC1E62 screen may not turn on if the air conditioner is not operating or if the power is turned off. Additionally, there may be an issue with the remote controller or its connection.
This answer is automatically generated