3.3.12 Recovery jumper JP1
On board, there is a 2-way jumper (JP1) that can be used to force i.MX6 processor in recovery mode.
For normal working of the board, this jumper must not be inserted. It has to be plugged only in case the system must be reprogrammed.
3.3.13 Boot Selection jumper J27
The onboard 2-way jumper J27 can be used to select boot source for the SBC-A62-J module.
When the jumper is inserted, then the boot will be performed from the uSD Card, otherwise, if the jumper is not placed, the boot will be performed from the internal
eMMC.

3.3.14 Power and Reset buttons

Power and Reset Connector - J30
Pin
Signal
1
ON_OFF
2
GND
3
RESET#
ON_OFF: Power switch input signal, open drain. This signal has to be connected to an external momentary pushbutton (contacts normally open).
Upon the pressure of this pushbutton (i.e., the signal is connected to GND), the pulse of this signal will let the switched voltage rails turn on or off.
RESET#: Reset switch input signal. This signal has to be connected to an external momentary pushbutton (contacts normally open). When the pushbutton is
pressed (i.e., the signal is connected to GND), the pulse of Reset signal will cause the reset of the board.
Please be aware that the power switch input signal and the reset switch input signal are also managed directly on the carrier board by the two pushbuttons SW2
and SW1 (respectively), so it is not mandatory to connect them externally using J30. Anyway, reset switch SW1 is optional.
SBC-A62-J
SBC-A62-J User Manual - Rev. First Edition: 1.0 - Last Edition: 2.3 - Author: S.B. - Reviewed by N.P. Copyright © 2016 SECO S.r.l.
To allow the integration of a SBC-A62-J based system inside a box PC-like, there is an optional connector on the
carrier board that allows to remote signals for the Power Button and for the Reset Button.
The dedicated connector is a 3-pin male connector, type MOLEX p/n 53398-0371 or equivalent, with
pinout shown in the table on the left.
Mating connector: MOLEX 51021-0300 crimp housing with MOLEX 50079-8000 crimp terminals.
Signals Description:
31