Siemens SICAM P38 Manual page 25

3-phase power meter with multi-tariff function
Table of Contents

Advertisement

Code list of optional settings in area A:
Data item
Phase voltage
Line voltage
Current
Neutral current
Active power
Reactive power
Apparent power
Power factor
Phase angle
Code list of optional settings in area B:
Data item
Import active power
Export active power
Total active power
Net active power
Import reactive power
Export reactive power 551 ... 557 558 ... 564 565 ... 571 572 ... 578 579 ... 582 583 ... 586 587 ... 590
Total reactive power
Net reactive power
Import active demand
Export active demand 699 ... 705 706 ... 712 713 ... 719 720 ... 726
Import reactive
demand
Export reactive
demand
Import apparent
demand
Export apparent
demand
Phase A forward
current demand
Phase B forward
current demand
Phase C forward
current demand
Frequency
Data
SICAM P38 P39, 3-phase Power Meter with Multi-Tariff function, User Manual
E50417-H8940-C564-4, Release Date 06.2018
Data type (current value)
Tran-
Maximun
Minimum
sient
(previous 1
(previous 1
to 3 months)
to 3 months)
0
1 (2 ... 4)
5 (6 ... 8)
9
10 (11 ... 13) 14 (15 ... 17) Current unbalance rate
18
19 (20 ... 22) 23 (24 ... 26) Voltage eligibility rate
27
28 (29 ... 31)
36
37 (38 ... 40) 41 (42 ... 44) Current distortion rate
45
46 (47 ... 49) 50 (51 ... 53) Fundamental voltage
54
55 (56 ... 58) 59 (60 ... 62) Fundamental current
63
/
64
/
Data: 7 continuous codes express total, tariff 1 to tariff 6 in order; 4 continuous
codes express current month, previous 1 to 3 months in order.
Previous
Current
1 month
351 ... 357 358 ... 364 365 ... 371 372 ... 378 379 ... 382 383 ... 386 387 ... 390
391 ... 397 398 ... 404 405 ... 411 412 ... 418 419 ... 422 423 ... 426 427 ... 430
431 ... 437 438 ... 444 445 ... 451 452 ... 458 459 ... 462 463 ... 466 467 ... 470
471 ... 477 478 ... 484 485 ... 491 492 ... 498 499 ... 502 503 ... 506 507 ... 510
511 ... 517 518 ... 524 525 ... 531 532 ... 538 539 ... 542 543 ... 546 547 ... 550
591 ... 597 598 ... 604 605 ... 611 612 ... 618 619 ... 622 623 ... 626 627 ... 630
631 ... 637 638 ... 644 645 ... 651 652 ... 658 659 ... 662 663 ... 666 667 ... 670
671 ... 677 678 ... 684 685 ... 691 692 ... 698
727 ... 733 734 ... 740 741 ... 747 748 ... 754
755 ... 761 762 ... 768 769 ... 775 776 ... 782
783 ... 789 790 ... 796 797 ... 803 804 ... 810
811 ... 817 818 ... 824 825 ... 831 832 ... 838
839 ... 845 846 ... 852 853 ... 859 860 ... 866
867 ... 873 874 ... 880 881 ... 887 888 ... 894
895 ... 901 902 ... 908 909 ... 915 916 ... 922
923
924
Data item
Voltage unbalance rate
V
Voltage distortion rate
/
Second harmonic
voltage ratio
/
Second harmonic
current ratio
Previous 2
Previous 3
month
month
Operation and Display
4.2 Cyclic Display
Data type (current
value)
nd
Transient 2
66
67
68
69
70
71
72 ... 120
121
120 ... 170
171
172 ... 219
220
221 ... 268
Phase A
Phase B
Phase C
th
to 50
/
/
/
/
/
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sicam p39

Table of Contents