When using an extension cord with your Wet/Dry Vac refer to the following table to determine the
required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord
are in good working conditions. Make repairs or replacements before using the vacuum cleaner.
Only use extension cords that are rated for outdoor use.
110V-120V
Amps
0-6
7-10
11-12
13-16
5
EXTENSION CORDS
Length of Extension Cord
25 Feet
50 Feet
7.5 Meter
15.25 Meters
18
18
16
14
100 Feet
30.5 Meters
A.W.G Wire Size
16
16
16
14
16
14
12
Not recommended
150 Feet
45.7 Meters
14
12
12