FIBRO Flex Cam Manual page 8

Hydraulic cylinders and tool slides for tool and mould-making and machinery construction
Table of Contents

Advertisement

Flex Cam
Stroke rate
The stroke rate is dependent on the minimum flow
opening, the volume of oil and the working and return
pressures. The connecting openings allow a working
stroke rate of up to 0.8 m/s. Although this is limited by
the extent to which the system heats up due to the
high stroke rates. The system temperature should not
exceed 60 °C.
Safety instructions
If the layout of the system gives the Force Cylinder an
excessive displacement volume due to excess over-
travel and/or seizing of the cylinder, the pressure in the
system can exceed the admissible value of 280 bar. In
critical situations, this effect will be counteracted by
the opening of a rupture valve at 517 bar.
The couplings are designed for a nominal pressure of
300 bar and 1000 bar rupture pressure.
On the gas side, the Accumulator is pressurised at 150
bar and is subject to Pressure Equipment Directive
97/23/EC.
To monitor safety during the process, we recommend
installing a control fitting as an additional check on the
gas side - see range of accessories.
Description
Force (magnitude)
Initial restoring force
Minimum gas pressure
Maximum gas pressure
Stroke length
Maximum speed
Maximum restoring speed
Maximum frequency
Ambient temperature
* not for 2018.11.01500.
** including +10 mm overtravel
1)
not for 2018.20.01500. and 2018.20.15000.
Table 1: Technical data
Values other than those specified in the above table
may be accepted under certain circumstances or if
different stroke lengths, speeds and frequencies are
combined.
8
Force Cylinders
2018.30.
kN
15
40
60
kN
2
5
8
bar
10
bar
40
mm
25, 50, 100
m/s
0,8
m/s
0,8
Strokes/min.
30
°C
10–40
Capacity and output
The forces listed in table 1 below are applicable for the
following nitrogen gas pressures:
Accumulator
Force Cylinder
Compact Cam
2018.11.01500..
Gas spring 2480.21. and .23.00000.
2018.11.06000.
Gas spring 2487.12.00350.
Compact Cam
2018.11.09000.
Gas spring 2480.12.00500.
2018.11.15000.
Gas spring 2487.12.00750.
Flange Cam
2018.12.04000.049
Gas spring 2480.21. and .23.00000.
Comments
The Accumulator and the Force Cylinder are pressure
vessels and as such are subject to the Pressure Equip-
ment Directive 97/23/EC.
During cutting and hole punching operations the nomi-
nal force of the Compact Cam should only be utilised
up to 75% to minimise impact during cutting which is
reinforced by the Accumulator. Impact during cutting
can be reduced by polished tool edges (e.g. roof
shape) and so downtime can be reduced.
Compact Cams
2018.11.
90
150
15
40 60
13
21
2
4
7
125
180
24, 49, 99*
0,8
0,8
60
10–40
and 2018.11.04000.
Flange
Cams
Power Unit
2018.12. 2018.20.
90 150
40
15
40 60 90 150
10 15
4
105
125
50
150
180
180
49
35**, 60**, 110**, 160**
0,8
0,8
0,8
0,8
30
60
60
10-40
10–40
subject to alterations
150 bar
20 bar
180 bar
180 bar
150 bar
150 bar
180 bar
(1)
60 30 30

Advertisement

Table of Contents
loading