FIBRO Flex Cam Manual page 39

Hydraulic cylinders and tool slides for tool and mould-making and machinery construction
Table of Contents

Advertisement

2018.11.09000.
2018.11.09000.
Install together with measuring hose and control fitting (gas spring and nitrogen connection are valveless).
Duplicate nitrogen gas ports for connecting the measuring hose.
Use only one port whilst keeping the other one closed.
30
20
32
Max.
stroke
10
2018.11.09000.
Compact Cam
Order No
2018.11.09000.024.1.
2018.11.09000.049.1.
2018.11.09000.099.1.
subject to alterations
.1
.1
Nitrogen gas connection
G
1
/
8
25
l
2
+0,02
ø12
(2x)
±0,015
10
+0,02
30
l
1
l
Locating pin
12 (2x)
65
e
.1
max.
stroke
e
24
159
268
49
184
293
99
234
343
Compact Cam 90 kN
with gas monitoring connection
Hydraulic connection
G
3
/
4
Venting M10x1
M16 fixing screw (4x)
l
l
l
1
2
236
158
261
208
311
283
Additional nitrogen gas
port G
1
/
8
120
76,5
25 25
±0,015
120
144
148
Note:
1)
The punch should preferably be mounted
in the middle of the piston rod.
It can also be located in the shaded area
if necessary.
A guide bolster with external guide to
absorb the lateral forces should be
provided for coping and cutting
operations.
Restoring force in kN
at 150 bar
Stroke start
Stroke end
10
14,6
10
14,4
10
14,2
39