FIBRO Flex Cam Manual page 62

Hydraulic cylinders and tool slides for tool and mould-making and machinery construction
Table of Contents

Advertisement

Flex Cam
Gas Spring Accessories
Diaphragm Pressure Switch/Gauging coupling
Installation Example:
diaphragm pressure
switch
2480.00.45.01
2480.00.45.02
connector
2480.00.24.02
hose
2480.00.23. ...
connector
2480.00.24.01
2480.00.24.01
Gauging coupling with valve for connection to
accumulator/cam unit
60
2480.00.45.01 50-200 bar
for accumulator
2480.00.45.02 10-50 bar
for cam unit
A/F 14
22
8
2480.00.24.
2480.00.45.
Technical Data of
Diaphragm Pressure
Switch
2480.00.45.01
switching range, adjustable 50– 500 bar
switching tolerance
overpressure protection
ø34
switching frequency
voltage (max.)
2480.00.45.02
switching range, adjustable 10– 50 bar
switching tolerance
overpressure protection
A/F 27
switching frequency (max.)
voltage (max.)
G
1
/
4
Circuit diagram for
diaphragm pressure switch
adapter
2480.00.45.10
valve connecting
G
1
/
8
2480.00.24.02
Gauging coupling with valve for connection to control armature
±3– 5 bar
600 bar
200/min
250 V
±3,0 bar
300 bar
200/min
250 V
2
4
P
1
A/F 19
21
10
subject to alterations
°