Electric Hydraulic Pump - FIBRO Flex Cam Manual

Hydraulic cylinders and tool slides for tool and mould-making and machinery construction
Table of Contents

Advertisement

Electric hydraulic pump

2018.80.15000
Start / Stop
(Switch off
when not in
use)
cable 10 m
CEE 16 A
connector
low pressure valve
high pressure valve
(see note)
oil tank
oil capacity
(Min. 10 litres)
Note!
The pressure can be set at both valves.
We recommend setting the low pressure valve to 25 bar.
The high pressure valve can be set to a maximum of 180 bar.
The value to be set depends on the operational requirements.
Technical specifications – hydraulic system
Oil tank volume
Hydraulic oil ISO VG 32
Min. flow at 120 bar
Max. flow at 25 bar
Oil pressure when extending and retracting 10-20 bar
Oil pressure during operation
Low and high pressure valves
Technical specifications – electrical system
Power supply electrical pump
Control voltage & control valve
max. oil temperature
Reset switch-on temperature after overheating
24
Contol signal 24 V – DC
Cam unit
Max.travel
(working unit)**
Travel 0
46
97,5
325
435
15 l
DIN 51524 HVLP (or similar)
1,6 l/min.
8,7 l/min.
max. 180 bar
(see note)
3x220-440 V-AC 50-60 Hz
24 V-DC
70+/–5° C
50°C
0
2018.80.15000
electric motor, 0,75 kW
manometer display
" oil connection for cam
1
/
2
(working unit)
oil level indicator / temperature sensor
ø11 (4x)
valve control voltage 24 V - DC
Oil filter
For continuous use we recommend
replacing the oil filter cartridge
(Order no. 2018.80.15000.002.1)
every 6 months
Cam speeds*
When extending and retracting
Size of cam
(Low pressure phase)
2018.11.01500.
115 mm/s
2018.11.04000.
47 mm/s
2018.11.06000.
29 mm/s
2018.11.09000.
18 mm/s
2018.11.15000.
12 mm/s
*
The table shows the approximate speeds of one cam unit
connected to an electric hydraulic pump. If several cam units are
connected to an electric hydraulic pump to obtain the speed of
each, divide by the numer of cam units.
Example: 3 x 2018.11.01500.024 : 115 mm/s = 38 mm/s
** The control signal (24 V DC) triggers extension of the piston
rodand the gas overpressure in the cam unit causes retraction.
Cam unit
(working unit)
during operation
(high pressure phase)
21 mm/s
9 mm/s
5 mm/s
3 mm/s
2 mm/s
subject to alterations
°

Advertisement

Table of Contents
loading

Related Products for FIBRO Flex Cam

Table of Contents