Flex Cam Accessories
Filling and Control Fitting, Filling hose
Charging Adapter
2480.00.32.21 Filling and control fitting
Valve
actuation
Screw-on unit
for connection
to gas spring
2480.00.31.02 Filling hose
Coupling for gas cylinder or pressure
regulator Connector thread W 24,32
2480.00.32.11
Charging adapter
54
Shut-off valve
1/14
M6
AF 13
G
1
/
8
2480.00.32.21
2480.00.31.02
2480.00.32.11
Description:
The filling and control
fitting 2480.00.32.21 is used
to fill, vary the pressure setting
pressure
(e.g. when testing tools) and
measure the gas pressure.
gauge
The coupling enables the
filling hose to be connected
directly to the gas cylinder
valve or the pressure regulator.
If the fitting is used solely for
Gas spring
checking purposes, a simpli-
fied arrangement not connec-
bleeder valve
ted to the gas cylinder is also
possible.
Closing the shut-off valve of
Quick release
the filling hose enables the
filling to be used to mea-
coupling – plug
sure the charging pressure in
connector
the accumulator / Cam Unit,
without detaching the hose.
For constant gas monitoring,
we recommend connecting a
control fitting 2480.00.30. or
2480.00.31.
The fitting is equipped as
standard with two adapters
Quick release
2480.00.32.10/.11 for
coupling – socket
connecting to various sizes
of coupling. (The adapter
required for charging both
Power Unit and Cam Unit is
2480.00.32.11).
Note:
2480.00.31.02 Filling hose
2 m long with quick release
coupling, shut-off valve and
gas bottle connector (order
separately).
Other filling hose lengths to
order.
°
subject to alterations