FIBRO Flex Cam Manual page 18

Hydraulic cylinders and tool slides for tool and mould-making and machinery construction
Table of Contents

Advertisement

Compact Cam 15 kN
2018.11.01500.
20
22
Max.
stroke
6,5
2018.11.01500.
Compact Cam
Order No
2018.11.01500.024
049
18
+0,02
ø8
(2x)
±0,015
7,5
+0,02
12
14
l
1
l
Locating pin
8 (2x)
e
33
Max.
stroke
e
24
94
49
119
2018.11.01500.
Hydraulic connection
G
1
/
2
Venting M10x1
M8 fixing screw (4x)
l
l
Stroke start
1
155,5
133,5
180,5
158,5
42
ø20
±0,015
44
56
59
Note:
1)
The punch should preferably be mounted
in the middle of the piston rod.
It can also be located in the shaded area
if necessary.
A guide bolster with external guide to
absorb the lateral forces should be
provided for coping and cutting
operations.
Restoring force in kN
at 180 bar
Stroke end
2
2,6
2
2,6
subject to alterations

Advertisement

Table of Contents
loading

Related Products for FIBRO Flex Cam