Easy Start Guide
Siemens V20 Series Inverter

1. Power and Motor Connections (Single Phase)

SUPPLY
Earth
PE
U
V
Phases
MOTOR
This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright
Drive Supermarket and must not be reproduced or altered without prior written permission.
Neutral
Live
L1
L2/N
L3
DANGER
RISK OF ELECTRIC
SHOCK! HAZARDOUS VOLTAGE PRESENT FOR
UP TO 5 MINUTES AFTER DISCONNECTION
FROM POWER SUPPLY! SEE INSTRUCTIONS!
W
DC- DC+
Earth
Before commencing, confirm that the
Inverter and all cables are completely
isolated from the power supply, have
been isolated for at least 5 minutes and
that the motor is not turning.
Notes:
The illustration on the left is based on the
smaller 230V Single Phase frame size model
(to 0.75kW). The terminal layout for larger
frame sizes is similar.
The order of the three motor phases
determines the direction the motor turns.
Use screened cable between the Inverter and
M o t o r. To m i n i m i s e e l e c t r o m a g n e t i c
interference, ensure the cable screen is
grounded.
©
The Inverter
Page 2