Ha Terminal (Hajem-A) - Panasonic CS-Z25UD3EAW Service Manual

Hide thumbs Also See for CS-Z25UD3EAW:
Table of Contents

Advertisement

14.7 HA Terminal (HAJEM-A)

Enable digital connection from indoor unit to external devices.
Control items:
1
Start/stop input.
2
Start/stop signal output.
Condition
1
1-2 (Pulse input): Unit ON/OFF condition switching with a pulse signal.
(1 pulse signal: shortage status 200~300msec)
2
3-4 (Static output): 5V output during the unit ON. No output at OFF.
Example of wiring:
Note: The wire length from indoor unit to the external interface must be within 1.9 meters. The wire must be double
insulation type and a ferrite core to be added to reduce noise. Proposed core spec is J0KE00000147 with Heat
Shrinkage Tube.
The signal between indoor unit and the external interface must be isolated by photo-coupler of approval type
(e.g: Semko, VDE etc).
200~300msec
ON/OFF input
(Pin 1-2)
Monitor output
(Pin 3-4)
Unit condition
MCU
Indoor Unit
PCB
#A K1KA04AA0347 (Maker: JST; Maker code: B4B-XH-TV4)
#B Maker: JST; Maker code: XHP-4
+5V
ON
OFF
+5V
Core
4T
#A4
#B4
1
1
HAJEM-A
240 mm
(XH type)
Max 1900 mm
79
ON
#B4
#A4
1
1