back plate and secure using the fixing screw. The strobe lamp will flash to confirm that the
tamper switch has been closed. The installation of your Siren & Strobe is now complete.
Solar panel
3 screws from DIP switch cover
Tamper switch
Battery connection
Initial Power Up
Battery 9 Volt
House Code
Alarm duration
DIP 1-8
DIP 9
Unit / Siren

Service Mode:

Press and hold the bottom button on the Remote Control. The Siren will produce two short
beeps/LED flashes and then after approximately 6 seconds a single long beep/LED flash
followed immediately by two short beeps/LED flashes to indicate that it has switched into
Service Mode. Now you can open the siren for service. At least once a year, preferably in the
autumn, the solar panel on the top of the siren housing should be cleaned using a soft, damp cloth.
This operation will ensure that the solar panel receives all of the available light.

Operating Mode:

Press and hold the middle button on the Remote Control. After approximately 6 seconds the
Siren will produce a single long beep/LED flash to indicate that it has switched into normal
operating mode.