Download Print this page

WimTec OCEAN S6 Assembly And Operating Instructions Manual page 26

Advertisement

Available languages

Available languages

EN
OCEAN S6
Assembly
7
!
ATTENTION!
Perform the following steps
in the order indicated!
26
Shower control
8
10
7.
Feed the connection cable 3 mand into the fl ush-mount set
and connect it to the power supply (art. no. 117 899 and art.
no. 113 792). See wiring diagram page 24. Attention: The po-
wer supply must not be installed in the fl ush-mount set!
8.
Connect the magnetic valves to the electronics module.
(no marking = rain shower, red = therm. disinfection)
9.
Feed the WimTec power cable 3m (with the electronics modu-
le and connect it to the power supply . Then turn on the power
supply. (This will cause the safety locking mechanism of the
magnetic valve to activate.)
10.
Connect the grounding wire (yellow) to the water path.
11.
Attach the mounting frame using the 4 screws supplied. Make
sure that the cable connections remain intact and the cables
are not crimped. When tightening the screws, ensure that the
mounting frame does not get warped.
WimTec OCEAN S6
9
11

Advertisement