OCEAN S6
DIP switches:
Program activation – DIP switches 1 and 2:
Program
Semi automatic mode
Fully automatic mode
Manual mode
Function activation – DIP switches 3–6:
DIP switch
Function
3
Shut-off delay ON = 5 s / OFF = 2 s
4
Warm water rinse
5
Protection from scalding
6
Stagnation rinse
Preset program.
1)
Only for models with thermal disinfection:
2)
Regulator controls:
D.
Range control
to detect user interaction
Sensor range preset to 70 cm
(configurable from 30 to
70 cm).
Sets the infrared sensor range
from 30–70 cm.
Automatic range adjustment
within the preset maximum
range.
DIP switch 1
OFF
1)
ON
OFF
2)
E.
Time control
set to safety flow arrest after
10 min (configurable from
10 s to 10 min).
Manual program mode: 10 s
to 60 s.
After the configured maximum
flow time has elapsed, the
water stops automatically to
prevent unintentional conti-
nuous activation.
DIP switch 2
Description
ON
Page 29
ON
Page 30
OFF
Page 31
Factory setting
OFF
ON
ON
OFF
F.
Interval control
for stagnation rinse
(configurable from 3 to 48 h).
If the fitting has not been
used for the set period, the
device will automatically
perform a 10-s rinse to flush
stagnant water from the
pipes.
WimTec OCEAN S6
Shower control
EN
Description
Page 32
Page 33
Page 34
23