Orifice
2.92mm
Full Vat
2.84mm
Split Vat
Use a leak detection fluid to find potentially dangerous gas leaks when making new connections.
A. Regulators can be adjusted in the field, but it is recommended that qualified service personnel ad-
just a regulator only if it is known to be out of adjustment or serious pressure fluctuations have
been found and cannot be solved another way.
B. Only qualified service personnel should make adjustments to the regulators.
C. Orifices: The fryer can be configured to operate on any available gas. The correct safety control
valve, appropriate gas orifices, and pilot burner are installed at the factory. While the valve can be
adjusted in the field, only qualified service personnel should make adjustments with proper test
equipment.
8. Check the programmed temperature thermostat setting. (Refer to chapter 1 FilterQuick™ Controller
Manual) for the setpoint programming instructions for your particular controller.)
2.4.2

Equipment Installed at High Altitudes

1.
The fryer input rating (BTU/hr) is for elevations up to 2,000 ft (610 m). For elevations above
2,000 ft (610m), the rating should be reduced four percent for each additional 1,000 ft (305m)
above sea level.
2.
The correct orifices are installed at the factory if operating altitude is known at time of the
customer's order.
2.5

Converting to another Gas Type

This appliance was configured at the factory for a specific type of gas. Converting from one type
of gas to another requires the installation of specific gas-conversion components. Conversion
instructions are included with conversion kits.
Switching to a different type of gas without installing the proper conversion components may
result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS
NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed by
qualified, licensed, and authorized installation or service personnel, as defined in Section 1.7 of
this manual.
AUSTRALIA ONLY
Burner Manifold Gas Pressures
Natural Gas
MJ/h
TPP
Orifice
73.8
1.0 kPa
1.95mm
36.9
each
1.0 kPa
1.95mm
73.8
total
CE Gas Conversion Kits
826-2937 — Natural to Propane
826-2938 — Propane to Natural
Propane Gas
MJ/h
TPP
73.8
2.05 kPa
36.9 each
2.05 kPa
73.8 total