2. Level fryers by adjusting the casters so that the fryer is level and at the proper height in the exhaust
hood. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge
of the hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour.
3. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle behind the fryer.
b. Ensure the easyTouch
c. Verify that the display indicates POWER OFF.
4. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is configured
for the proper type of gas before connecting the fryer quick-disconnect device or piping from the
gas supply line.
Fryers MUST be connected ONLY to the gas type identified on the attached rating plate.
5. Verify the minimum and maximum gas supply pressures for the type of gas to be used in accordance
with the accompanying tables below.
Non- CE Standard for Incoming Gas Pressure
Gas Type
Min Pressure W.C/kpa/mbar
Max Pressure W.C/kpa/mbar
CE Standard for Incoming Gas Pressure
Gas Type
Pressure (mbar) (1) mbar=10,2mm H
Australia Standard for Incoming Gas Pressure
Gas Type
Min Pressure W.C/kpa/mbar
Max Pressure W.C/kpa/mbar
Korea Standard for Incoming Gas Pressure
Gas Type
Min Pressure W.C/kpa/mbar
Max Pressure W.C/kpa/mbar
When pressure-testing incoming gas supply lines, disconnect the fryer from the gas line if the
test pressure is ½" PSI [3.45 kPa (14 inches W.C.)] or greater to avoid damage to the fryer's gas
piping and gas valve(s).
NOTE: External gas regulators are not normally required on this fryer. A safety control valve protects the
fryer against pressure fluctuations. If the incoming pressure is in excess of ½" PSI (3.45 kPa/35 mbar), a
step-down regulator is required.
®
Touch screen powers up.
DANGER
FQG60T
Nat
6/1.49/14.93
14.00/3.48/34.84
FQG60T
G20
0
20
20 or 25
2
FQG60T
Nat
4.54/1.13/11.30
14.00/3.48/34.84
FQG60T
LNG (Natural)
4/1.00/10.00
10/2.50/25.00
DANGER
2-5
LP
11/2.74/27.37
14.00/3.48/34.84
G25
G30
28/30 or 50
LP
11.05/2.75/27.50
14.00/3.48/34.84
LPG (Propane)
9.2/2.30/23.00
13.2/3.30/33.00
G31
37 or 50