Heat Dissipation
The QSW-4600-52ТX full gigabit switch is designed with fans. To ensure good dissipation, sufficient space (10 cm
distance from both sides and the back panel of the chassis) should be reserved for ventilation. It is recommended to clean
the switch at regular intervals (like once every 3 months). Especially, avoid dust from blocking the screen mesh on the
back of the cabinet; otherwise, the temperature of the device may go too high and affects the performance.
LEDs
LED
System status LED
10/100/1000 Base-T copper
port status LED
SFP+ fiber port status LED
1.3 QSW-4600-28ТX-POE
Technical Specifications
Model
CPU
www.qtech.ru
Panel Marker
Status
Status
Blinking green
Solid green
Solid red
1-48
Off
Solid green
Solid yellow
Blinking
49F-52F
Off
Solid green
Blinking
QSW-4600-28ТX-POE
Single-core CPU with the clock speed of 1.0G
Indication
The system is being initialized.
The switch is operational..
Over-temperature, the system will reboot.
The switch is faulty.
The port is not connected.
The port is connected at 1000 Mbps.
The port is connected at 10/100 Mbps
Data are being transceived at the port.
The port is not connected.
The port is connected.
Data are being transceived at the port.