QTech QSW-4600-12T-POE Hardware Installation And Reference Manual

Advertisement

Quick Links

HARDWARE INSTALLATION AND REFERENCE GUIDE
QSW-4600-12T-POE Switch
Hardware Installation and Reference Guide V1.0
www.qtech.ru

Advertisement

Table of Contents
loading

Summary of Contents for QTech QSW-4600-12T-POE

  • Page 1 HARDWARE INSTALLATION AND REFERENCE GUIDE QSW-4600-12T-POE Switch Hardware Installation and Reference Guide V1.0 www.qtech.ru...
  • Page 2 This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain the latest information through the QTECH website. QTECH endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
  • Page 3 It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts. Obtaining Technical Assistance  QTECH Website: http://www.qtech.ru  Technical Support: https://helpdesk.qtech.ru/ Related Documents...
  • Page 4: Product Overview

    The SFP+ ports support both 10Gbase-R and 1000base-X modules. The SFP ports support both 1000 base-X and 100base-X modules. 1000Base-T is compatible with 100Base-TX and 10Base-T in the downlink direction. The PoE ports support IEEE 802.af/at PoE. 1.1 QSW-4600-12T-POE Technical Specifications Model QSW-4600-12T-POE...
  • Page 5 QSW-4600 Series Switch Hardware Installation and Reference Guide Supports 1000base-X only. For details, see Appendix B. Optical Module The supported module type may change at any time. Contact QTECH for details. Supports 1000Base-X SFP modules. SFP Port  AC input...
  • Page 6 Dimensions (W x D x H) Weight 2,5 kg (with package) The QSW-4600-12T-POE switch is a class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. Product Appearance On the front panel, the QSW-4600-12T- Ethernet switch provides 10 10/100/1000Base-T Ethernet ports, 2 SFP ports, and 1 Console port.
  • Page 7 Power cord specification: 10A Heat Dissipation The QSW-4600-12T-POE adopts fanless design, thereby ensuring normal function of the device in the specified environment. 10 cm distance space should be reserved at both sides and the back plane of the cabinet to allow air circulation.
  • Page 8 System status LED Status The switch is not receiving power. Blinking green The system is being initialized. Continuous blinking indicates errors. Solid green The switch is operational. Solid yellow Temperature warning Check the working environment of the switch immediately. www.qtech.ru...
  • Page 9 Solid yellow The PoE port is abnormally operational. 1000Mbps SFP port 11F-12F The port is not connected. status LED Solid green The port is connected at 1000 Mbps. Blinking green The port is receiving or transmitting traffic at 1000 Mbps. www.qtech.ru...
  • Page 10: Preparation Before Installation

    Any nonstandard and inaccurate electric operation may cause an accident such as fire or electrical shock, thus causing severe even fatal damages to human bodies and equipment. Direct or indirect touch through a wet object on high-voltage and mains supply may bring a fatal danger. www.qtech.ru...
  • Page 11: Static Discharge Damage Prevention

    If the dust is unavoidable, keep the door and window away from the pollution source.  The machine room should be away from the residential area. Otherwise, the machine room should meet the construction standard in terms of noise. www.qtech.ru...
  • Page 12: Temperature And Humidity

    In an environment with high temperature, the equipment is subject to even greater harm, as its performance may degrade significantly and various hardware faults may occur. Therefore, the ambient temperature and humidity of the QSW-4600 series must meet the requirements listed in Table 2-1: www.qtech.ru...
  • Page 13 Table 2-3 Requirements for Harmful Gases in the Equipment Room Average (mg/m3) Maximum (mg/m3) Both average and maximum value are measured for a week. The switch cannot be placed in the environment with the maximum density for over 30 minutes every day. .. www.qtech.ru...
  • Page 14 All the above constitute the comprehensive grounding requirements. The resistance of earth wires should be less than 1 ohm. The QSW-4600 series switch back plane is reserved with one grounding pole, as shown in Figure 2-1. Figure 2-1Grounding of QSW-4600 www.qtech.ru...
  • Page 15: Lightning Resistance

    2.3 Requirements of Installation Tools Table 2-4 List of Installation Tools Common Tools Phillips screwdriver, flathead screwdriver, related electric cables and optical cables, bolts, diagonal pliers, straps Anti-static tools Special Tools www.qtech.ru...
  • Page 16 QSW-4600 Series Switch Hardware Installation and Reference Guide Meters Multimeter The tool kit is customer-supplied. www.qtech.ru...
  • Page 17: Product Installation

    Reserve a spacing of at least 10 cm around the chassis for good ventilation. Do not stack the devices.  The switch should be located at places free from the large power radio launch pad, radar launch pad, and high-frequency large-current devices. If necessary, electromagnetic shielding should be adopted. For example, use interface cables to shield cables. www.qtech.ru...
  • Page 18: Mounting The Switch On The Wall

    The QSW-4600 series switch can be mounted on the wall, as shown in the following figure. Attach the mounting brackets to the switch with the supplied screws, as shown in Figure 3-4. Figure 3-4 Attaching the Mounting Brackets to the Switch for Wall-Mounting www.qtech.ru...
  • Page 19: Mounting The Switch On A Table

    Figure 3-2 Attaching the Switch on the Wall 3.3.3 Mounting the Switch on a Table Attach the four rubber feet to the recessed areas on the bottom of the switch, as shown in Figure 3-6. Figure 3-6 Attaching the Rubber Feet to the Recessed Areas www.qtech.ru...
  • Page 20: Checking After Installation

    Check that all interface cables are laid out inside the equipment room. In the case of external cabling, check that the lightning resistance socket or network interface lightning protector is connected.  Check that sufficient airflow is available around the device (over 10 cm) www.qtech.ru...
  • Page 21: System Debugging

    Step 2:Set terminal parameters. The parameters are as follows: baud rate 9600, data bit 8, parity check none, stop bit 1, and flow control as none. Choose Setup>Program>Attachment >Communication> Hyper Terminal. Choose Cancel, the interface as shown in figure 4-2 is displayed. Figure 4-2 www.qtech.ru...
  • Page 22 Figure 4-3 After choosing the serial port, click OK to display the serial port parameter setting interface, set the baud rate to 9600, data bit to 8, parity check to none, stop bit to 1 and flow control to none. www.qtech.ru...
  • Page 23: Startup Check

    4.2.2 Checking after Program Startup (Recommended) After power-on, you are recommended to perform the following checks to ensure the normal operation of follow-up configurations.  Check whether information is displayed on the terminal interface. www.qtech.ru...
  • Page 24 Check whether the status of the switch indicator is normal.  Check whether the main program of the device is normally loaded.  Check whether the time on the device is consistent with the current Beijing time.  Check whether the service interface forwards data normally. www.qtech.ru...
  • Page 25: Maintenance And Troubleshooting

    Make sure that the serial port is connected firmly, and the parameters are set correctly.  Make sure that the optical fibers or cables are correctly connected to the ports.  Contact QTECH Customer Service Department. 5.2 Troubleshooting Common Faults Symptom Possible Causes...
  • Page 26 Power off, install the module, and then power on module is not is in loose contact. the host. identified by the host. The module is installed after the host is Power off, remove and install the module again. powered on. www.qtech.ru...
  • Page 27: Appendix A Connectors And Connection Media

    100-ohm Category-5 cables for 100 Mbps, both of which can be up to 100 m. Figure A-2 shows the pinouts of the 100BASE-TX/10BASE-T. Figure A-2 Pinouts of the 100BASE-TX/10BASE-T Figure A-3 shows the straight-through and crossover cable connections for the 100BASE-TX/10BASE-T. Figure A-3 Connections of the Twisted Pairs of the 100BASE-TX/10BASE-T www.qtech.ru...
  • Page 28 Series Switch Hardware Installation and Reference Guide Optical Fiber Connection For the optical fiber ports, select single-mode or multiple-mode optical fibers for connection according to the fiber module connected. The connection schematic diagram is shown in Figure A-4: Figure A-4 Optical Fiber Connections www.qtech.ru...
  • Page 29: Appendix B Lightning Protection

    L line is on the left and the N line is on the right, the polarity of the arrester power cable shall be reversed; if the LED is still Red, it is confirmed that the arrester PE terminal has not been grounded. www.qtech.ru...
  • Page 30 The Ethernet port arrester is not provided, the user can purchase them to address their own practical requirements. For the detailed information during the arrester installation, please refer to Ethernet Port Arrester Hardware Installation Guide, which contains the technical specification and the maintenance and installation of the arrester. www.qtech.ru...
  • Page 31 Use the multimeter to confirm the contact condition after the grounding.  Incomplete arrester installation. If there is more than one port connected to the peer device on the switch, it needs to install the arresters on all connection ports for the purpose of the lightning protection. www.qtech.ru...
  • Page 32: Appendix C Cabling Recommendations In Installation

    During cabling of an optical fiber, the bend radius of the fiber should be equal to or greater than 10 times the diameter of the fiber. Precautions for Bundling up Cables  Before bundling cables, correctly mark labels and stick the labels to cables where appropriate.  Cables should be neatly and properly bundled, as shown in Figure C-1. www.qtech.ru...
  • Page 33 Proper buckles should be selected to bundle up cables. It is forbidden to connect two or more buckles to bundle up cables.  After bundling up cables with buckles, you should cut off the remaining part. The cut should be smooth and trim, without sharp corners, as shown in Figure C-2. www.qtech.ru...
  • Page 34 The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled. When the moving part reaches the installation position, the remaining part should not touch heat sources, sharp corners, or sharp edges. If heat sources cannot be avoided, high-temperature cables should be used. www.qtech.ru...
  • Page 35 Power cables of the same type and in the same cabling direction should be bundled up into cable bunches, with cables in cable bunches clean and straight.  Binding by using buckles should be performed according to Table C-1. Cable Bunch Diameter (mm) Binding Space (mm) 80-150 10-30 150-200 200-300 www.qtech.ru...
  • Page 36 No knot is allowed in cabling or bundling.  For solder-less terminal blocks (such as air switches) of the cold pressing terminal type, the metal part of the cold pressing terminal should not be exposed outside the terminal block when assembled www.qtech.ru...