Page 3
3.7 Mounting the Switch to a Cabinet 3.8 Connecting the System Ground 3.9 Installing Power Supplies 3.10 Installing Fans 3.11 Installing Modules 3.12 Installing Swappable Interface Modules (Optional) 3.12.1 Installing SFP+/SFP Modules 3.12.2 Installing SFP+ Cables 3.13 Connecting the Power Cord 3.14 Installation Verification www.qtech.ru...
Page 4
7.6 Removing PoE Frame 8 CABLES 8.1 Connecting the External Port Cables 8.2 Bundling the Cables 9 APPENDIX A CONNECTORS AND MEDIA 10 APPENDIX B SWITCH LIGHTNING PROTECTION 11 APPENDIX C CABLING RECOMMENDATIONS IN INSTALLATION 12 APPENDIX D SITE SELECTION www.qtech.ru...
Page 5
QTECH reserves all copyrights of this document. Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of QTECH is prohibited.
Page 6
It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts. Obtaining Technical Assistance ❖ QTECH Website: https://www.qtech.ru ❖ Technical Support Website: https://helpdesk.qtech.ru ❖...
Hardware Installation 1. Product Overview 1 PRODUCT OVERVIEW Launched by QTECH independently, QSW-7600 series next generation core switches adopt the crossbar/FULLMESH architecture and support dual supervisor modules and power supply redundancy. ❖ The QSW-7608: supports dual supervisor modules and provides six service module slots.
Page 8
QSW-7608 switch is a class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. Product Appearance The hardware system of the QSW-7608 switch is composed of the chassis, the power system, modules and the cooling system. www.qtech.ru...
Page 9
The air filters are on the right side of the chassis. Figure 1-1 Appearance of the QSW-7608 Switch Front Panel The front panel of the QSW-7608 switch is shown in Figure 1-2. Figure 1-2 Front Panel of the QSW-7608 Switch www.qtech.ru...
Page 10
Ensure the supervisor module, service module, and power supply module are removed from the chassis before you move or transport the QSW-7608 chassis. Back Panel The back panel of the QSW-7608 switch is shown in Figure 1-3. Figure 1-3 Back Panel of the QSW-7608 Switch www.qtech.ru...
Page 11
❖ PoE power supply input: The QSW-PA3000I-PL and the QSW-PA1600I-PL power supply modules are supported. The two types of power supply modules support power management. The supervisor module of the QSW-7608 switch can read the power supply information and implement flexible and intelligent power management. www.qtech.ru...
Page 12
Figure 1-4 Ventilation and Heat Dissipation System of the QSW-7608 Switch (Air Intakes) 3. Air intakes for system power 1. Air intakes for PoE power modules Note: modules 2. Air intakes for service and supervisor modules Figure 1-5 Ventilation and Heat Dissipation System of the QSW-7608 Switch (Exhaust Vents) www.qtech.ru...
10cm around the chassis. If any module slot is unoccupied, install a filler panel to ensure proper airflow. 1.2 QSW-7605 Specifications Model QSW-7605 Module Slot two supervisor module slots and three service module slots Supervisor QSW-M7605-CM www.qtech.ru...
Page 14
1℃ as the altitude ranging from 3000m to 5000m increases by 200m. Operation height: 5000m max Storage height: 5000m max Operating 0°C to 50°C Temperature Storage -40°C to 70°C Temperature Operating 10% to 90% RH (non-condensing) Humidity MTBF 200,000 hours www.qtech.ru...
Page 15
❖ The cooling system is composed of the fan trays. Fan trays are at the back of the chassis. Figure 1-65 Appearance of the QSW-7605 Switch Front Panel The front panel of the QSW-7605 switch is shown in Figure 1-7. Figure 1-7 Front Panel of the QSW-7605 Switch www.qtech.ru...
Page 16
The operating environment temperature of the QSW-7605 switch ranges between 0 and 50°C. The thermal design must satisfy the requirement on the device's reliability in the temperature range while ensuring the device's safety and maintainability. According to the thermal design www.qtech.ru...
Page 17
For the supervisor and service modules, air flows across the chassis from the right intakes to the back vents. For the power supply modules, air flows in from the front intakes and out from the back vents. www.qtech.ru...
QSW-PA1600I: 90-180V~ Power: 1200W; 180-264V~ Power: 1600W QSW-PD600I: -40VDC to -75VDC Power: 600W QSW-PD1600I: -40VDC to -75VDC Power: 1400W Power Supply The power supply redundancy of the same model is supported. Redundancy Fan Module QSW-M10-FAN EMC Standards GB9254-2008 CLASS A, FCC CLASS A www.qtech.ru...
Page 19
❖ The QSW-7610 switch provides two supervisor module slots, eight service module slots and two switching fabric module slots. The supervisor modules support 1+1 redundancy. Users are recommended to configure redundancy for the supervisor modules. Users may choose different service modules as needed. www.qtech.ru...
Page 20
❖ The cooling system is composed of the fan trays. Fan trays are at the back of the chassis. Figure 1-11 Appearance of the QSW-7610 Switch Front Panel The front panel of the QSW-7610 switch is shown in Figure 1-12. Figure 1-12 Front Panel of the QSW-7610 Switch www.qtech.ru...
Page 21
The module is faulty. Blinking Initiation is in progress. Continuous blinking Green indicates a failure. Solid Green Initiation is complete. Switching fabric The module is NOT in position or NOT module status receiving power. Solid Green The module is operational. www.qtech.ru...
Page 22
3. Switching fabric module slot Ensure the supervisor module, service module, and power supply module are removed from the chassis before you move or transport the QSW-7610 chassis. Power supply The QSW-7610 switch adopts the AC and DC power supply. www.qtech.ru...
Page 23
Figure 1-14 Ventilation and Heat Dissipation System of the QSW-7610 Switch (Air Intakes) 3. Air intakes for supervisor and 1. Air intakes for power modules Note: switching fabric modules 2. Air intakes for service modules Figure 1-15 Ventilation and Heat Dissipation System of the QSW-7610 Switch (Exhaust Vents) www.qtech.ru...
The modules of the QSW-7600 switch provide 10/100/1000M auto-sensing Ethernet copper ports, 1000 Mbps/100 Mbps SFP (single-mode/multi-mode) optical fiber interfaces and 10G/40G optical fiber interfaces. 1.4.1 QSW-M7608-CM QSW-M7608-CM is the supervisor module of the QSW-7608 series switches and is designed with management and switching functions. www.qtech.ru...
Page 25
After the collection is complete, the device restarts automatically. Hold the button for a while and release it, the device restarts automatically in five seconds. Identification Status Meaning on the panel System LED Status The module is NOT receiving power. Solid red The module is faulty. www.qtech.ru...
Page 26
Solid red The power supply module is faulty. MGMT port status MGMT The MGMT port is NOT connected. Green The MGMT port is connected at 1000Mbps. Yellow MGMT port connected 10/100Mbps. Blinking The MGMT port is transmitting or receiving data. www.qtech.ru...
Page 27
Operating 0°C to 50°C Temperature Storage -40°C to 70°C Temperature Operating 10% to 90% RH (non-condensing) Humidity MTBF 312,000 hours Weight Net weight: 2.1 kg Dimensions 438.5 mm x 309.0 mm x 40.1 mm (W x D x H) www.qtech.ru...
Press the button, and the system starts to collect information, during which the device will not restart. After the collection is complete, the device restarts automatically. Hold the button for a while and release it, the device restarts automatically in five seconds. www.qtech.ru...
Page 29
The MGMT port is NOT connected. Green The MGMT port is connected at 1000Mbps. Yellow MGMT port connected 10/100Mbps. Blinking The MGMT port is transmitting or receiving data. Specifications Model QSW-M7605-CM Quad-core CPU, each core with the clock speed of 1.0G BOOTROM 8 MB www.qtech.ru...
The QSW-M7605-CM adopts the CR2032 lithium battery. The device may explode if a wrong battery model is used. Used batteries should be properly disposed of. 1.4.3 QSW-M7610-CM QSW-M7610-CM is the supervisor module of the QSW-7610 series switches and is designed with management and switching functions. www.qtech.ru...
Page 31
FE card. Otherwise, packet loss may occur. When there is only one supervisor module, the OFL button will lose effect. Identification Status Meaning on the panel System LED Status The module is NOT receiving power. www.qtech.ru...
Page 32
The power module is operational. Green Solid Red A failure occurred. Switching fabric The switching fabric module is not in module LED position or powered off. Solid The switching fabric module is operational. Green Solid Red A failure occurred. www.qtech.ru...
Page 33
DDR4 4GB External Port One Console port; One 10/100/1000M MGMT port; One USB port Button One FUNC button and one OFL button Power <50W Consumption Hot Swapping Supported Management Supported Redundancy EMC Standards GB9254-2008 CLASS A Safety GB4943-2011 Standards www.qtech.ru...
QSW-M7600-24SFP/12GT4XS-EB supports 10G SFP+ and Gigabit SFP modules. 10G SFP+ modules cannot be used as Gigabit SFP modules. Identification Status Meaning on the panel System LED Status The module is NOT receiving power. Solid red The module is faulty. www.qtech.ru...
Page 35
QSW-M7600-24SFP/12GT4XS-EB Quad-core CPU, each core with the clock speed of 1.0G BOOTROM 8 MB Flash 512 MB Memory SDRAM DDRIII 1 GB Port Type 12 10/100/1000BASE-T RJ45 ports, 24 SFP ports and 4 SFP+ ports Transmission 10/100/1000BASE-T Cat-5 UTP www.qtech.ru...
Page 36
Operating 0°C to 50°C Temperature Storage -40°C to 70°C Temperature Operating 10% to 90% RH (non-condensing) Humidity MTBF 335,000 hours Weight Net weight: 2.90 kg Dimensions 438.5 mm x 309.0 mm x 40.1 mm (W x D x H) www.qtech.ru...
The port is connected at 10Mbps or 100Mbps. Blinking The port is transmitting and receiving data. SFP port LED Link/ACT The port link is NOT connected. Solid green The port is connected at 1000Mbps. Solid yellow The port is connected at 100Mbps. www.qtech.ru...
RJ45 ports support 10/100/1000Mbps auto-negotiation. And the SFP+ ports support 10G SFP+ modules, Gigabit SFP modules and hot swapping. The copper ports at 10/100Mbps do not support half-duplex mode. QSW-M7600-48GT4XS-EB supports 10G SFP+ and Gigabit SFP modules. 10G SFP+ modules cannot be used as Gigabit SFP modules. Identification Status Meaning www.qtech.ru...
Page 40
Quad-core CPU, each core with the clock speed of 1.0G BOOTROM 8 MB Flash 512 MB Memory SDRAM DDRIII 1 GB Port Type 48 RJ45 ports and 4 SFP+ ports Transmission 10/100/1000BASE-T Cat-5 UTP Medium 1000BASE-SX (850nm) Multi-mode optical fiber 1000BASE-LX (1310nm) Single-mode optical fiber www.qtech.ru...
Operating 10% to 90% RH (non-condensing) Humidity MTBF 329,000 hours Weight Net weight: 2.80 kg Dimensions 438.5 mm x 309.0 mm x 40.1 mm (W x D x H) 1.4.7 QSW-M7600-48SFP4XS-EB Module Appearance Figure 1-29 Appearance of the QSW-M7600-48SFP4XS-EB www.qtech.ru...
Page 42
SFP+ port LED Link/ACT The port link is NOT connected. Solid green The port is connected. Blinking The port is transmitting and receiving data. Specifications Model QSW-M7600-48SFP4XS-EB Quad-core CPU, each core with the clock speed of 1.0G BOOTROM 8 MB www.qtech.ru...
Page 43
Single-mode optical fiber 10GBASE-ZR (1550nm) Single-mode optical fiber Status, Link/ACT Hot Swapping Supported Power <101W Consumption GB9254-2008 CLASS A Standards Safety GB4943-2011 Standards Operating 0°C to 50°C Temperature Storage -40°C to 70°C Temperature Operating 10% to 90% RH (non-condensing) Humidity www.qtech.ru...
Initialization is in progress. Continuous blinking indicates errors. Solid green The module is operational GT port LED Link/ACT The port link is NOT connected. Solid green The port is connected at 1000Mbps. Solid yellow The port is connected at 10/100Mbps. www.qtech.ru...
Page 45
SFP ports while not supported by SFP+ ports. 100BASE-FX (1550nm) Single-mode optical fiber, supported by SFP ports while not supported by SFP+ ports. 1000BASE-SX (850nm) Multi-mode optical fiber 1000BASE-LX (1310nm) Single-mode optical fiber 1000BASE-LH (1310nm) Single-mode optical fiber 1000BASE-ZX (1550nm) Single-mode optical fiber www.qtech.ru...
Operating 10% to 90% RH (non-condensing) Humidity MTBF 334,000 hours Weight Net weight: 2.85 kg Dimensions 438.5 mm x 309.0 mm x 40.1 mm (W x D x H) 1.4.9 QSW-M7600-32XS4QXS-DA Module Appearance Figure 1-31 Appearance of the QSW-M7600-32XS4QXS-DA www.qtech.ru...
Page 47
QSFP+ port LED Link/ACT The port link is NOT connected. Solid green The port is connected. Blinking The port is transmitting and receiving data. Specifications Model QSW-M7600-32XS4QXS-DA Quad-core CPU, each core with the clock speed of 1.5G BOOTROM 16 MB www.qtech.ru...
Page 48
40GBASE-LR4 Single-mode optical fiber Status, Link/ACT Hot Swapping Supported Power <210W Consumption GB9254-2008 CLASS A Standards Safety GB4943-2011 Standards Operating 0°C to 50°C Temperature Storage -40°C to 70°C Temperature Operating 10% to 90% RH (non-condensing) Humidity MTBF 398,000 hours www.qtech.ru...
The port is NOT connected. Solid green The port is connected. Blinking The port is transmitting and receiving data. QSFP+ port LED Link/ACT The port is NOT connected. Solid green The port is connected. Blinking The port is transmitting and receiving data. www.qtech.ru...
Page 50
Status, Link/ACT Hot Swapping Supported Power <245W Consumption GB9254-2008 CLASS A Standards Safety GB4943-2011 Standards Operating 0°C to 50°C Temperature Storage -40°C to 70°C Temperature Operating 10% to 90% RH (non-condensing) Humidity MTBF 346,000 hours Weight Net weight: 3.7 kg www.qtech.ru...
Solid green The module is operational Offline LED Switching service is in progress. The module cannot be removed. Solid green Release the Offline button and wait for 2s before removing the module. Specifications Model QSW-M7610-FE-D I www.qtech.ru...
10% to 90% RH (non-condensing) Humidity MTBF 460,000 hours Weight Net weight: 1.9 kg Dimensions 371.0 mm x 248.0 mm x 43.0 mm (W x D x H) 1.4.12 QSW-PA1600I-F Module Appearance Figure 1-34 Appearance of the QSW-PA1600I-F Module www.qtech.ru...
Page 53
Solid red There is no power input or input undervoltage. Solid green Solid red Overvoltage. Solid green Solid red Overcurrent. Solid green Solid orange Temperature alarm Solid green Solid red Over-temperature fault Solid green Solid red PSR on/off Specifications www.qtech.ru...
When you plug the power cable into the power supply, pull down the retention clip over the plug on the power cable. Operation Altitude: 5000m max. Storage Altitude: 5000 max. 1.4.13 QSW-PA600I-F Module Appearance Figure 1-35 Appearance of the QSW-PA600I-F Module www.qtech.ru...
Page 55
There is no power input or input undervoltage. Solid green Solid red Overvoltage Solid green Solid red Overcurrent Solid green Solid orange Temperature alarm Solid green Solid red Over-temperature fault Solid green Solid red PSR on/off Specifications Module QSW-PA600I-F www.qtech.ru...
When you plug the power cable into the power supply, pull down the retention clip over the plug on the power cable. Operation Altitude: 5000m max. Storage Altitude: 5000 max. 1.4.14 QSW-PD600I-F Module Appearance Figure 1-36 Appearance of the QSW-PD600I-F Module External Port The QSW-PD600I module provides one DC (-48V) power port. www.qtech.ru...
Page 57
Solid red Phase loss protection Solid green Solid red Fan failure Specifications Module QSW-PD600I-F Model Rated -48VDC Voltage Range Max Voltage -40VDC to -75VDC Range Power 600W Output Weight Net weight: 1.30 kg Power Cord 20A power cord Requirement www.qtech.ru...
10A power cord. Indicator Status Meaning Status LED A power fault occurs or there is no power input Solid green The module is operational Specifications Module QSW-PA300I-F Model Rated 100 to 120 VAC, 200 to 240 VAC; 50/60 Hz Voltage Range www.qtech.ru...
The QSW-PA1600I module provides 12 VAC input to the overall system of the QSW-7610 switch. The front panel of the power supply module provides a 3-pin power port, which can be connected to standard 16A power cord. Meaning DC/FLT www.qtech.ru...
When you plug the power cable into the power supply, pull down the retention clip over the plug on the power cable. Operation Altitude: 4000m max. Storage Altitude: 4000 max. 1.4.17 QSW-PA600I Module Appearance Figure 1-39 Appearance of the QSW-PA600I Module www.qtech.ru...
Page 61
There is no power input or input undervoltage. Solid green Solid red Overvoltage. Solid green Solid red Overcurrent. Solid green Solid orange Temperature alarm Solid green Solid red Over-temperature fault Solid green Solid red PSR on/off Specifications Module QSW-PA1600I Model www.qtech.ru...
When you plug the power cable into the power supply, pull down the retention clip over the plug on the power cable. Operation Altitude: 4000m max. Storage Altitude: 4000 max. 1.4.18 QSW-PD1600I Module Appearance Figure 1-40 Appearance of the QSW-PD1600I Module www.qtech.ru...
Page 63
Solid red PSR on/off Solid green Solid red Phase loss protection Solid green Solid red Fan failure Specifications Module QSW-PD600I Model Rated -48VDC Voltage Range Max Voltage -40VDC to -75VDC Range Power 1400W Output Weight Net weight: 1.60 kg www.qtech.ru...
Figure 1-41 Appearance of the QSW-PD600I Module External Port The QSW-PD600I module provides one DC (-48V) power port. Meaning DC/FLT Solid green Solid green The module is operational Solid green Solid red There is external power supply. The power module is not in use. www.qtech.ru...
When you plug the power cable into the power supply, pull down the retention clip over the plug on the power cable. Operation Altitude: 2000m max. Storage Altitude: 2000 max. 1.4.20 QSW-M76-PSE Figure 1-42 Appearance of the QSW-M76-PSE Module www.qtech.ru...
PoE2 is the right one of marked on Figure 1-15). Specifications Dimensions 400mm x 439mm x 43mm (W x D x H) Weight Net weight: 3.50 kg 1.4.21 QSW-PA3000I-PL Module Appearance Figure 1-44 Appearance of the QSW-PA3000I-PL Module www.qtech.ru...
Page 67
Meaning Alarm Fault Solid green The module is operational There is no power input Blinking The module is in standby green mode Solid green Solid yellow Persistent overcurrent. Solid green Solid yellow Temperature alarm Solid red Over-temperature causes power-off www.qtech.ru...
176 to 210 VAC Power: 2500 W 210 to 264 VAC Power: 3000W Weight Net weight: 2.10 kg Power Cord 16A power cord Requirement Operation Altitude: 5000m max. Storage Altitude: 5000 max. 1.4.22 QSW-PA1600I-PL Module Appearance Figure 1-45 Appearance of the QSW-PA1600I-PL Module www.qtech.ru...
Page 69
QSW-M76-PSE. Meaning Alarm Fault Solid green The module is operational There is no power input Blinking The module is in standby green mode Solid green Solid yellow Persistent overcurrent. Solid green Solid yellow Temperature alarm Solid red Over-temperature causes www.qtech.ru...
90 to 176 VAC Power: 1000 W Output 176 to 264 VAC Power: 1600 W Weight Net weight: 1.70 kg Power Cord 16A power cord Requirement Operation Altitude: 5000m max. Storage Altitude: 5000 max. 1.4.23 QSW-M08-FAN Module Appearance Figure 1-47 Appearance of the QSW-M08-FAN Module www.qtech.ru...
Page 71
167.5 mm x 132 mm x 133 mm (W x D x H) Status Meaning Status The fan is NOT receiving power or fails. Solid green The fan is operational. Features Function Meaning Status Rotational speed monitoring, failure alarm Monitoring Automatic Speed-adjustment controlled by temperature www.qtech.ru...
There is one QSW-M08-FAN tray with two fans and one fan control board. The QSW-M05-FAN draws air out to form convection for heat dissipation. Specifications Fan Model QSW-M08-FAN Dimension 167.5 mm x 132 mm x 133 mm (W x D x H) Status Meaning Status The fan is NOT receiving power or fails. www.qtech.ru...
The QSW-M10-FAN is the fan for service modules and supervisor modules on the QSW-7610. There is one QSW-M10-FAN tray with six fans and one fan control board. The QSW-M10-FAN draws air out to form convection for heat dissipation. Specifications Fan Model QSW-M10-FAN www.qtech.ru...
Page 74
The fan is NOT receiving power or fails. Solid green The fan is operational. A fan fails. Features Function Meaning Status Rotational speed monitoring, failure alarm Monitoring Automatic Speed-adjustment controlled by temperature Speed- adjustment Hot Swapping Hot swapping is supported by the fan tray. www.qtech.ru...
❖ Please observe local regulations and specifications when performing electrical operations. Relevant operators must be qualified. ❖ Please carefully check for any potential danger in the working area, for example, ungrounded power supply, unreliable grounding of the power supply and damp/wet ground or floor. www.qtech.ru...
The QSW-7600 series switches are equipped with an anti-static wrist strap. Please refer to Figure 2-1 for the position of the jack for the wrist strap.
❖ Do not stare into any fiber port. Do not stare into any fiber port under any circumstances, as this may cause permanent damage to your eyes. www.qtech.ru...
0ºC to 50ºC -40ºC to 70ºC The ambient temperature is measured at the point that is 1.5m above the floor and 0.4m before the equipment when there is no protective plate in front or back of the equipment rack. www.qtech.ru...
The equipment room should be protected from the intrusion of harmful gases (for example, SO S, NO and Cl ), whose requirements are listed in the following table. www.qtech.ru...
M7600-48SFP4XS-EA) + 2 x 80W (QSW-M7600-36GT12SFP4XS-EA) + 176W (reserved power consumption for the whole switch) = 668W. It is recommended that you adopt one QSW-PA1600I-F or two QSW-PA600I-F modules. The following table lists the power consumption of each module: QSW-7608 Series Modules Maximum Power Consumption (W) www.qtech.ru...
Page 81
The rated leakage non-action current of a leakage protector shall be 50% of the leakage action current. Take a leakage protector www.qtech.ru...
2.2.9 EMI Consideration Various interference sources, from either outside or inside the equipment or application system, affect the system in the conductive ways such as capacitive coupling, inductive coupling, and electromagnetic radiation. There are two types of electromagnetic interferences: www.qtech.ru...
Make sure the cabinet complies with the following conditions: ❖ Install the switch in a 19-inch cabinet in 4-port form hold. ❖ Be sure the distance between two square hole strips, one on each side, is 465 mm. ❖ Figure 2-2 19-inch Cabinet www.qtech.ru...
A normal delivery should contain the above mentioned items, which may differ from the actual delivery, depending on purchase contracts. Please check your goods carefully against the packing list or purchase contract. If you have any questions or there are any errors, please contact your distributor. www.qtech.ru...
3.2 Installation Verification The QSW-7600 is complicated equipment, so you must carefully plan and arrange the installation location, networking mode, power supply, and wiring before installation. Verify the following before installation: ❖ The installation location is of a good air flow. www.qtech.ru...
1. Insert the air filter along the slide rail. Note the instruction on the air filter to ensure that the air filter is installed properly. 2. Tighten the captive screws on the air filter with a screwdriver. Figure 3-2 Installing the Air Filter of the Supervisor Module and Service Module on QSW-7608 Switch www.qtech.ru...
1. Insert the frame into the slot along the rail. Note the direction identifier of the frame to ensure the correct direction. 2. Tighten the captive screws on the power module to fix it. Figure 3-3 Installing the PoE frame on the QSW-7608 www.qtech.ru...
3-5. 3. Align the screw holes on the cable management bracket with those on the chassis and tighten the screws, as shown in figure 3-5. Figure 3-5 Mounting the Cable Management Bracket for QSW-7605 www.qtech.ru...
2. Mount the cabinet at the designed location as planned. 3. Install the appropriate cable management bracket and cables. 4. Install the tray and wiring layer on the rack according to the configuration of one rack with one cabinet installed or one rack with multiple cabinets installed. www.qtech.ru...
Page 91
It is recommended to install the power socket after planning on available space properly. Otherwise, there may be problems for operation. www.qtech.ru...
Install seven cage nuts on the marked square holes on each bracket as shown in figure 3-7. Figure 3-7 Slide Rail Installation Positions Place the switch on the slide rail, and drive it smoothly into the cabinet until the front bracket reaches the square hole strip. www.qtech.ru...
2. Attach the one end of the grounding wire to the switch with the two screws. Connect the other end of the grounding wire to the grounding wire of the cabinet. Figure 3-9 Grounding Point on the Rear of the QSW-7608 Switch www.qtech.ru...
3.9 Installing Power Supplies The QSW-7608 series switches provide two system power supplies: QSW-PA1600I-F and QSW- PA600I-F AC power supplies, and two PoE power supplies: QSW-PA3000I-PL and QSW-PA1600I- PL. The QSW-7605 series switches provide two system power supplies: QSW-PA300I-F and www.qtech.ru...
Page 95
3. Tighten the captive screws on the power module to fix it. Figure 3-11 Installing Power Supplies ❖ Install the PoE power system Take the same installation steps as the AC power installation. www.qtech.ru...
1. Install the fan tray into the fan slot in the rear panel of QSW-7608. Note the direction identifier of the fan tray’s name to ensure the correct direction. 2. Tighten the captive screws on the fan tray with a screwdriver. 3. Figure 3-13 Installing QSW-M08-FAN Fan Tray www.qtech.ru...
Always wear an anti-static wrist strap when installing the module and the metallic part of the anti-static wrist strap should be fully touched with the skin. Besides, for the sake of security, please not touch any component of the module. www.qtech.ru...
Page 98
①Supervisor module slot ②Service module slot Figure 3-16 QSW-7605 Chassis Note: ①Supervisor module slot ②Service module slot ❖ Install modules See the following figure for installing the supervisor module and the service module. Steps for installing the QSW-7608 module: www.qtech.ru...
Page 99
2. Insert the module into the slot along the rail and drive it ahead smoothly (② in figure 3- 18). 3. Push both levers toward the slot (③ in figure 3-18). 4. Tighten captive screws on both sides of the panel (④ in figure 3-18). Figure 3-18 Installing the QSW-7605 module www.qtech.ru...
2. Use the fiber optical patch cord to connect the SFP/SFP+ module to the fiber optical network. Select the patch cord with the connector corresponding to the port. 3. After the patch cord is connected, the Link/ACT Status LED is on. Otherwise, please check connection of the patch cord. www.qtech.ru...
After the cable is plugged, make sure that the bending radius is greater than 5 times of the cable diameter. Too small bending radius may cause damage to the copper cable. For example. If the cable diameter is 4.9mm, the bending radius should be 24.5mm at least, as shown in figure 3-35: www.qtech.ru...
3. Install the retention clip on the front panel of the power module 4. Pull down the retention clip over the plug on the power cable.. 5. Connect the other end of the power cord to an external power socket. Figure 3-23 Connecting the Power Cord on QSW-7608 www.qtech.ru...
❖ Verify if the external power supply matches the distribution panel of the cabinet. ❖ After installing the equipment, verify if the front/back cabinet doors can be closed. ❖ Verify that the cabinet has been fastened completely, and does not move or tilt. www.qtech.ru...
Page 104
❖ Verify that the rated current of the external power socket is greater 16A and that the socket is grounded well. ❖ Verify that each power module is connected to a power socket. ❖ Verify that the vacant slot is covered with a filler panel for ventilation and heat dissipation. www.qtech.ru...
❖ Set terminal parameters. The parameters are as follows: baud rate 9600, data bit 8, parity check none, stop bit 1, and flow control as none. Details are as follows: 1. Choose Start > Programs > Accessories > Communications > Hyperterminal. The hyperterminal window appears. www.qtech.ru...
Page 106
4. After selecting the serial port, click OK. The Serial Port Parameter Setting window is displayed, as shown in Figure 4-4. Set the baud rate to 9600, data bit to 8, parity check to none, stop bit to 1, and flow control to none. Figure 4-4 www.qtech.ru...
Checking After Power-on (Recommended) After power-on, you are recommended to perform the following checks to ensure the normal operation of follow-up configurations. ❖ Check that information appears on the terminal interface. ❖ Check that the device indicator is normal. www.qtech.ru...
❖ Fan and power supply working status ❖ Temperature status For the monitoring commands, see QSW-7600 series Software Configuration Guide. QSW-7600 supports remote maintenance. If QSW-7608 and the Internet are connected, the user can log in to the QSW-7600 via Telnet and maintain QSW-7600 remotely through various monitoring commands.
Page 109
Replacing Fuses To replace the old fuse wire with the correspondent new one, please contact the technical support representatives of QTECH. The following table lists the specifications for the module fuses. Module...
Check the installation and fastening of the modules Check the indicators on the modules Check the connection of the serial port and its parameters Check the connection of the fibers or cables of various ports Contact Technical Support of QTECH for hardware problems www.qtech.ru...
Fault 4: The LED of the supervisor module is abnormal. Fault Description: The LED of the supervisor module becomes abnormal after the supervisor module is powered on or works for some time. For example, the Status LED is blinking or OFF, and the Alarm LED is red. www.qtech.ru...
Page 112
QSW-7600 Software Configuration Guide. If not, modify the serial port configuration parameters. If there is still no serial port printed information, please contact QTECH Customer Service Department for technical support.
Page 113
4. Check whether the rates of the two sides match and whether the optical fiber type meets requirements. In addition, for ports supporting different rates, check whether rate modes are configured correctly. If above mentioned methods do not take effect, please contact QTECH for technology assistance. www.qtech.ru...
4. Figure 7-1 Installing and Removing the Air Filter of QSW-7608 Supervisor and Service Modules Note A: Air filters to be removed B: Air filters to be installed 7.2 Removing Swappable Interface Modules (Optional) 7.2.1 Removing SFP+/SFP Modules Take the following steps to remove SFP/SFP+ modules: 1. Unplug the optical fiber. www.qtech.ru...
❖ Immediately install the dust plug to the module port and the switch fiber port. 7.3 Replacing Modules Preparation 1. Wear an anti-static wrist strap close to your skin and have it properly grounded. 2. Take out the module from the package. 3. Take the following steps to replace the module: www.qtech.ru...
Page 116
8. Drive the levers close to the module, and the module will hit the back panel. The module will be fastened after self-locking of levers. 9. Figure 7-4 Replacing the Module (for QSW-7608) Figure 7-5 Replacing the Module (for QSW-7605) www.qtech.ru...
Do not touch the connecting finger on the power module which has been removed to avoid being electrocuted in case of incomplete discharge. Take the following steps to remove the power module on QSW-7608: 1. Unplug the cable. Separate the pigtail plug of the cable from the connector of the power module. www.qtech.ru...
Page 118
3. Drag the power module panel with one hand and support the bottom of the power module with the other hand to pull out the power module. 4. Insert the power module into the slot until it clicks into place. Figure 7-7 Removing the Power Module on QSW-7605 www.qtech.ru...
3. Insert the fan tray into the slot along the slide rail until the fan tray hits the back panel. 4. Tighten the captive screws on the fan tray with the Phillips screwdriver. Figure 7-8 Removing the Fan for QSW-7608 www.qtech.ru...
2. Pull out the frame and put it in the anti-static bag. 3. Insert the frame into the slot along the slide rail until it hits the back panel. 4. Tighten the captive screws on the frame with the Phillips screwdriver. Figure 7-10 Removing the PoE power frame for QSW-7608 www.qtech.ru...
Page 121
Hardware Installation 7. Replacing Modules Note: A: PoE power frame modules to be B: PoE power frame modules to be removed installed www.qtech.ru...
2. On the both sides of the chassis, fasten the fibers and twisted pairs to the cabinet cable management ring or bracket. 3. For the power cables, you should bundle them closely along the bottom of the chassis, in a straight line wherever possible. www.qtech.ru...
10BASE-T uses Category 3, 4, 5 100-ohm UTP/STP and 1000BASE-T uses Category 5 100-ohm UTP/STP for connections. Both support a maximum length of 100 meters. Figure A-2 shows100BASE-TX/10BASE-T pin assignments. Figure A-2 100BASE-TX/10BASE-T Pin Assignments. Figure A-3 shows wiring of straight-through and crossover cables for 100BASE-TX/10BASE-T. Figure A-3 100BASE-TX/10BASE-T Connection www.qtech.ru...
Page 124
Hardware Installation 9. Appendix A Connectors and Media Fiber Connection You can choose to use single mode or multimode fibers according to the transceiver module types. Figure A-4 shows connection of fiber cables. Figure A-4 Fiber Connection www.qtech.ru...
N line is on the left and the L line is on the right, the arrester PE terminal is not grounded; if the L line is on the left and the N line is on the right, the polarity of the www.qtech.ru...
Page 126
IN, while the adapter cable connected to the switch is connected to the end of OUT) and observe whether the LED on the borad is normal or not. 5. Use the nylon button to bundle the power cables. Figure B-2 Schematic Diagram for the Ethernet port Arrester Installation www.qtech.ru...
Page 127
❖ Incomplete arrester installation. If there is more than one port connected to the peer device on the switch, it needs to install the arresters on all connection ports for the purpose lightning protection. www.qtech.ru...
10 times the diameter of the fiber. Precautions for Cable Bundling ❖ Before bundling cables, correctly mark labels and stick the labels to cables where appropriate. ❖ Cables should be neatly and properly bundled, as shown in Figure C-1. Figure C-1 Bundling Cables www.qtech.ru...
Page 129
❖ If cables are to be bent, bind them first but do not tie cable ties within the bend to avoid stress on the cables, which may otherwise cause the wires inside to break, as shown in Figure C-3. www.qtech.ru...
Page 130
❖ When using screws to fasten cable lugs, the bolts or nuts shall be tightened and prevented from loosening, as shown in Figure C-4. Figure C-4 Fastening Cable Lugs 3. Spring washer 1. Flat washer Note 4. Flat washer 2. Nut www.qtech.ru...
Page 131
10 to 30 150 to 200 200 to 300 ❖ Do not tie knots for cables or cable bundles. ❖ The metal parts of the cold-pressed terminal blocks, such as air circuit breakers, shall not be exposed outside of the blocks. www.qtech.ru...
❖ Sulfur-containing materials are forbidden. ❖ Pay attention to the location of the air conditioner. Keep the air conditioner from blowing wind straight toward the device or blowing water drops from the window or air vent toward the device. www.qtech.ru...