QTech QSW-6300 Series Hardware Installation And Reference Manual

Table of Contents

Advertisement

Quick Links

HARDWARE INSTALLATION AND REFERENCE GUIDE
QSW-6300 Series Switches
Hardware Installation and Reference Guide
www.qtech.ru

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QSW-6300 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for QTech QSW-6300 Series

  • Page 1 HARDWARE INSTALLATION AND REFERENCE GUIDE QSW-6300 Series Switches Hardware Installation and Reference Guide www.qtech.ru...
  • Page 2: Table Of Contents

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Contents 1. PRODUCT OVERVIEW 1.1. QSW-6300 Series Switches 1.2. Package Contents 1.3. QSW-6300-32T 1.3.1. Technical Specifications 1.3.2. Product Appearance 1.3.2.1. Front Panel 1.3.2.2. Rear Panel 1.3.3. Power Supply 1.3.4. Heat Dissipation System 1.3.5.
  • Page 3 QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 2.1.3. Electric Safety 2.1.4. Electrostatic Discharge Safety 2.1.5. Laser Safety 2.2. Installation Environment Requirements 2.2.1. Ventilation Requirements 2.2.2. Temperature/Humidity Requirements 2.2.3. Cleanliness Requirements 2.2.4. Grounding Requirements 2.2.4.1. Safety Grounding 2.2.4.2. Lightning Grounding 2.2.4.3.
  • Page 4 QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 4.2.2. Checking Environment after Power-on (Recommended) 5. MONITORING AND MAINTENANCE 5.1. Monitoring 5.1.1. Indicator 5.1.2. CLI Commands 5.2. Maintenance 5.2.1. Ventilation System Maintenance 5.2.2. Power Supply Module Maintenance 5.2.3. Replacing Lithium Battery 5.2.4.
  • Page 5: Product Overview

    Note: The QSW-6300 series switch is a class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
  • Page 6: Package Contents

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 1.2. Package Contents Item Quantity Switch Mounting Bracket Rubber Pad Mounting Bracket Installation Guide M4x8 Phillips Countersunk Screw, GB819- Grounding Cable Management Software (Pre-installed) 1.3. QSW-6300-32T 1.3.1. Technical Specifications Model QSW-6300-32T Dual-core with the clock speed of 1.2 GHz...
  • Page 7 QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Model QSW-6300-32T Power Supply  2 slots Module Slot  Supported AC module: The switch supports QSW-M-6300- AC input: Rated voltage: 100 V AC to 240 V AC Maximum voltage: 90 V AC to 264 V AC...
  • Page 8: Product Appearance

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Model QSW-6300-32T Weight 4.4 kg (9.70 lbs.) 1.3.2. Product Appearance The QSW-6300-32T Ethernet switch provides 24 10/100/1000 BASE-T Ethernet ports, eight 10GE SFP+ ports, one MGMT port, one USB port, and one Console port on the front panel, two power supply module slots and one expansion slot on the back panel.
  • Page 9: Rear Panel

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 1.3.2.2. Rear Panel Figure 1-3 Rear Panel of QSW-6300-32T Note: Grounding Lug Filler Panel (Expansion Module) Filler Panel (Non-expansion Module) Power Module Slot 1 Power Module Slot 2 1.3.3. Power Supply QSW-6300-32T supports 2 power supply modules.
  • Page 10: Led

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 1.3.5. LED Panel Status Meaning Identification System status Status The switch is not powered on. Blinking Initialization is in progress. green Continuous blinking indicates a (3 Hz) fault. Blinking It is used for on-site positioning...
  • Page 11: Qsw-6300-52T

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Panel Status Meaning Identification MGMT port status MGMT Blinking The port is receiving or green transmitting data at 1000 Mbps. Solid yellow The port is connected at 10/100 Mbps. Blinking...
  • Page 12 QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Model QSW-6300-52T SFP Module SFP+ interface Type SFP module, SFP BIDI module SFP+ module, SFP+ cable, SFP+ BIDI module See Appendix B. Note: The module types may update without prior notification. Please contact QTECH Networks for details.
  • Page 13: Product Appearance

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Model QSW-6300-52T Temperature Supported Alarming GB9254-2008CLASS A Certification Safety GB4943-2011 Regulation Compliance Dimensions 440 mm x 340 mm x 44 mm (17.32 in. x 13.39 in. x 1.73 in.) (W x D x H) Weight 4.5 kg (9.92 lbs.)
  • Page 14: Rear Panel

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Console Port 10/100/1000Base-T Ethernet Port Port Status LED 10GE SFP+ Port USB Port 10. MGMT Port 1.4.2.2. Rear Panel Figure 1-7 Rear Panel of QSW-6300-52T Grounding Lug Filler Panel Filler Panel (Non-expansion Module)
  • Page 15: Led

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 1.4.5. LED Panel Status Meaning Identification System status Status The switch is not powered on. Blinking Initialization is in progress. green Continuous blinking indicates a (3 Hz) fault. Blinking It is used for on-site positioning...
  • Page 16: Qsw-6300-32F

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Panel Status Meaning Identification MGMT port status MGMT Solid yellow The port is connected at 10/100 Mbps. Blinking The port is receiving or yellow transmitting data at 10/100 Mbps. 10GE SFP+ port 49F-52F The port is not connected.
  • Page 17 QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Model QSW-6300-32F SFP Module SFP+ interface Type SFP module, SFP BIDI module SFP+ module, SFP+ cable, SFP+ BIDI module See Appendix B. Note: The module types may update without prior notification. Please contact QTECH Networks for details.
  • Page 18: Product Appearance

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Model QSW-6300-32F GB9254-2008CLASS A Certification Safety GB4943-2011 Regulation Compliance Dimensions 440 mm x 340 mm x 44 mm (17.32 in. x 13.39 in. x 1.73 in.) (W x D x H) Weight 4.3 kg (9.48 lbs.)
  • Page 19: Rear Panel

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview GE SFP Port 10GE SFP+ Port Status LED 10. 10GE SFP+ Port 11. USB Port 12. MGMT Port 1.5.2.2. Rear Panel Figure 1-11 Rear Panel of QSW-6300-32F Grounding Lug Filler Panel (Expansion module)
  • Page 20: Led

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 1.5.5. LED Panel Status Meaning Identification System status Status The switch is not powered on. Blinking Initialization is in progress. green Continuous blinking indicates a (3 Hz) fault. Blinking It is used for on-site positioning of...
  • Page 21: Power Supply Modules

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview Panel Status Meaning Identification MGMT port MGMT Blinking The port is receiving or status LED yellow transmitting data at 10/100 Mbps. GE SFP port 1F-16F The port is not connected.
  • Page 22: Specifications

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview QSW-M-6300-PWR are AC modules providing an output voltage of 12 V and an output power of up to 150 W. Note:  The switch can be powered on by either one power supply module or dual power supply modules.
  • Page 23: Features

    QSW-6300 Series Switches Hardware Installation and Reference Guide Product Overview 1.6.1.2. Features Feature Description Conformal Coating Protects circuits against moisture, frog, mold, electrical shock and leakage, and so on. Protection Provides undervoltage protection, output overcurrent protection, output overvoltage protection and output short circuit protection.
  • Page 24: Preparing For Installation

    QSW-6300 Series Switches Hardware Installation and Reference Guide Preparing for Installation 2. PREPARING FOR INSTALLATION 2.1. Safety Precautions Note:  To avoid personal injury and equipment damage, please carefully read the safety precautions before you install the QSW-6300 series. ...
  • Page 25: Electrostatic Discharge Safety

    Keep the indoor installation environment clean and dust-free.  Maintain appropriate humidity conditions. 2.1.5. Laser Safety Among the modules supported by the QSW-6300 series, here are many transceiver modules that are Class I laser products. Precaution:  When a fiber transceiver works, ensure that the port has been connected with a fiber or covered by a dust cap to keep out dust and prevent it from burning your eyes.
  • Page 26: Cleanliness Requirements

    Hydrogen sulfide (H Nitrogen dioxide (NO Chlorine gas (CI 2.2.4. Grounding Requirements A good grounding system is the basis for stable and reliable running of the QSW-6300 series and is indispensable for preventing lightning strikes and interference. Please carefully check the...
  • Page 27: Safety Grounding

    QSW-6300 Series Switches Hardware Installation and Reference Guide Preparing for Installation grounding conditions at the installation site according to the grounding specifications, and complete grounding properly based on the actual situation. Note: Correct grounding is the key to prevent lightning strikes and resist interference and must be performed by users.
  • Page 28: Emi Consideration

    List of Tools Common Tools Phillips screwdriver, flat-head screwdriver, wires, network cables, fastening bolts, diagonal pliers, and binding straps Special Tools Anti-static tools Meters Multimeter Note: The QSW-6300 series switch is delivered without a tool kit. Please prepare a tool kit yourself.
  • Page 29: Installing The Switch

    QSW-6300 Series Switches Hardware Installation and Reference Guide Installing the Switch 3. INSTALLING THE SWITCH Note: Please ensure that you have carefully read Chapter 2 and make sure that the requirements in Chapter 2 are all met. 3.1. Installation Procedure 3.2.
  • Page 30: Mounting The Switch Into A Cabinet

    3.3.1. Mounting the Switch into a Cabinet The QSW-6300 series switches follow the EIA standard dimensions and can be installed in 19- inch cabinet. During the installation, place the front panel on the front part of the bracket. For safety, fasten screws to secure the bracket on the switch.
  • Page 31: Installing And Removing The Power Supply Module

    QSW-6300 Series Switches Hardware Installation and Reference Guide Installing the Switch 3.4. Installing and Removing the Power Supply Module Wear anti-static gloves before the following operations. 3.4.1. Installing the AC Power Supply Module Step 1: Take out a new power supply module and ensure that the input mode and input indicators of the power supply module meet requirements.
  • Page 32: Connecting The Ground Cable Of The Switch

    QSW-6300 Series Switches Hardware Installation and Reference Guide Installing the Switch 3.5. Connecting the Ground Cable of the Switch A PGND is installed on the back of QSW-6300(M5*12PWM screws. First connect the PGND to the grounding terminal of the cabinet and then connect the grounding terminal to the grounding bar of the equipment room.
  • Page 33: Simple Bundling Steps

    QSW-6300 Series Switches Hardware Installation and Reference Guide Installing the Switch 3.7.1. Simple Bundling Steps  Bind the drooping part of the fibers and twisted pairs of each board, and lead them to both sides of the chassis for convenience.
  • Page 34: Verifying Operating Status

    QSW-6300 Series Switches Hardware Installation and Reference Guide Verifying Operating Status 4. VERIFYING OPERATING STATUS 4.1. Setting up Configuration Environment 4.1.1. Setting up Configuration Environment Connect the PC to the management port of the switch through a network cable, as shown in Figure 4-1.
  • Page 35 QSW-6300 Series Switches Hardware Installation and Reference Guide Verifying Operating Status Figure 4-2 In the Connectivity Note window, enter the name of the new connection and click OK. A window appears as shown in Figure 4-3. In the Connect Using field, select the serial port you want to use.
  • Page 36: Checking Environment Before/After Power-On

    QSW-6300 Series Switches Hardware Installation and Reference Guide Verifying Operating Status Figure 4-4 After setting the serial port parameters, click OK. The Hyperterminal window appears. 4.2. Checking Environment before/after Power-on 4.2.1. Checking Environment before Power-on  Check whether the switch is properly grounded.
  • Page 37: Monitoring And Maintenance

    Working status of fan and power supply  Temperature status Note: For the monitoring commands, refer to QSW-6300 Series Switch RGOS Configuration Guide. 5.2. Maintenance 5.2.1. Ventilation System Maintenance  The fan module responsible for heat dissipation is equipped with the fault monitoring signal.
  • Page 38: Replacing Lithium Battery

    The built-in lithium batteries can support the real time clock of the QSW-6300 switch without external power supply. To replace lithium batteries, please contact technical support personnel of QTECH Networks. The technical support personnel will select lithium batteries of the same specifications for replacement.
  • Page 39: Troubleshooting

    QSW-6300 Series Switches Hardware Installation and Reference Guide Troubleshooting 6. TROUBLESHOOTING 6.1. General Troubleshooting Procedure 6.2. Common Troubleshooting Procedures 6.2.1. Fault 1: The system login password is lost. [Fault Description] The system login password of the switch is forgotten or lost, and so it is not possible to configure the data.
  • Page 40: Fault 3: The Serial Port Console Has No Output

    [Troubleshooting] Such a problem is related to the settings of the serial port. Check if the settings of such parameters as the baud rate match those in QSW-6300 Series Switch RGOS Configuration Guide. 6.2.5. Fault 5: The newly-inserted service card module fails to be powered on.
  • Page 41 QSW-6300 Series Switches Hardware Installation and Reference Guide Troubleshooting  Check whether the rates of the two sides match and whether the optical fiber type meets requirements. In addition, for ports supporting different rate, check whether rate modes are configured correctly.
  • Page 42: Appendix

    QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix 7. APPENDIX 7.1. Appendix A Connectors and Media 7.1.1. 1000BASE-T/100BASE-TX/10BASE-T Port The 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and uses the cable of 100-ohm Category-5 or Supper Category-5 UTP or STP, which can be up to 100 m (328 feet).
  • Page 43: Optical Fiber Connection

    QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix Figure A-3 Connections of the Twisted Pairs of the 100BASE-TX/10BASE-T 7.1.2. Optical Fiber Connection For the optical fiber ports, select single-mode or multiple-mode optical fibers for connection according to the fiber module connected. The connection schematic diagram is shown in Figure...
  • Page 44: Installing The Ethernet Port Arrester

    QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix Grounding and polarity detection indicator: If the indicator is red, cable connection is incorrect (the ground cable is not connected, or the N and L lines are reversely connected). Check your power supply line.
  • Page 45: Appendix D Cabling

    QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix paper for the double-sided adhesive tape and paste the Ethernet port arrester to the switch housing. The paste position for the Ethernet port arrester should be as close to the ground terminal of the switch as possible.
  • Page 46: Requirement For The Minimum Cable Bend Radius

    QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix cables are routed beside the cabinet, and top cabling or bottom cabling is adopted according to the actual situation in the equipment room, such as the positions of the DC power distribution box, AC socket, or lightning protection box.
  • Page 47 QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix  The cable management brackets and cabling troughs inside and outside the cabinet should be smooth without sharp corners.  The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining.
  • Page 48 QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix  220 V and -48 V power cords must not be bundled on the guide rails of moving parts.  The power cords connecting moving parts such as door grounding wires should be reserved with some access after being assembled to avoid suffering tension or stress.
  • Page 49: Appendix E Site Selection

    QSW-6300 Series Switches Hardware Installation and Reference Guide Appendix 7.4. Appendix E Site Selection  The equipment room should be at least 5 km away from heavy pollution sources, such as the smelter works, coal mine, and thermal power plant. The equipment room should be at least 3.7 km away from medium pollution sources, such as the chemical factory,...
  • Page 50: Общая Информация

    неработающие ссылки и замечания к навигации по документу. Если вы хотите написать нам по поводу данного документа, то используйте, пожалуйста, форму обратной связи на qtech.ru. 8.2. Гарантия и сервис Процедура и необходимые действия по вопросам гарантии описаны на сайте QTECH в разделе «Поддержка» −> «Гарантийное обслуживание».

This manual is also suitable for:

Qsw-6300-32tQsw-6300-52tQsw-6300-32f

Table of Contents