installation
Horizontal Venting with Two (2) 90
One 90
elbow = Two 45
o
Option
V
A)
3' Min.
B)
5' Min.
C)
8' Min.
With these options, maximum total
pipe length is 30 feet with minimum
of 8 feet total vertical and maximum
4 feet total horizontal.
Please note minimum 1 foot
between 90
elbows is required.
o
Lengths do not include elbow indicated
Vent restrictor position A (fully
open), Refer to the "Venting Ar-
rangement" section.
Vertical Venting with Two (2) 90
One 90
elbow = Two 45
o
Option
V
A)
1' Min.
1' Max.
B)
1' Min.
2' Max.
C)
2' Min.
3' Max.
D)
2' Min.
4' Max.
With these options, max. total pipe length is 30 feet with
min. of 4 feet total vertical and max. 4 feet total horizontal.
Please note min. 1 foot between 90
Lengths do not include elbow indicated
Vent restrictor position A (fully open). Refer to the "Venting
Arrangement" section.
|
22
Regency
U39E-11 ULTIMATE™ Freestanding Gas Stove
®
Elbows
o
elbows
o
H + H1
2' Max.
3' Max.
4' Max.
Elbows
o
elbows
o
H
V1
V + V1
1' Min.
2' Min.
2' Min.
3' Min.
2' Min.
4' Min.
2' Min.
4' Min.
elbows is required.
o
.