42
For Infinity (3 HP pump unit)
Disconnect Switch Types & Accessories
1 Phase 3 H.P. Pump Unit
2 Pole 240V 1 PH
Required Auxiliary Contact
Required Type "D" Fuse (Buss type "FRN" or equal)
3 Phase 3 H.P. Pump Unit
3 Pole 208V 3 PH
Required Auxiliary Contact
Required Type "D" Fuse (Buss type "FRN" or equal)
Cab Lighting
1 Pole Solid Neutral 120V 1 PH
Required Type "D" Fuse (Buss type "T" or equal)
For Infinity HD (5 HP pump unit)
Disconnect Switch Types & Accessories
1 Phase 5 H.P. Pump Unit
2 Pole 240V 1 PH
Required Auxiliary Contact
Required Type "D" Fuse (Buss type "FRN" or equal)
3 Phase 5 H.P. Pump Unit
3 Pole 208V 3 PH
Required Auxiliary Contact
Required Type "D" Fuse (Buss type "FRN" or equal)
Cab Lighting
1 Pole Solid Neutral 120V 1 PH
Required Type "D" Fuse (Buss type "T" or equal)
Infinity and Infinity HD Planning Guide
Cutler Hammer
Federal Pioneer
1HD221N
1322SN
DS16CP
E1K-1AEV-W94
2@30 amp
2@30 amp
1HD321N
1332SN
DS16CP
E1K-1AEV-W94
3@20 amp
3@20 amp
GP 111N
86211
1@15 amp
1@15 amp
Cutler Hammer
Federal Pioneer
1HD221N
1322SN
DS16CP
E1K-1AEV-W94
2@40 amp
2@40 amp
1HD321N
1332SN
DS16CP
E1K-1AEV-W94
3@30 amp
3@30 amp
GP 111N
86211
1@15 amp
1@15 amp
Siemens
ID321
MSSAK 116
2@30 amp
ID321
MSSAK 116
3@20 amp
CFN 211
1@15 amp
Siemens
ID321
MSSAK 116
2@40 amp
ID321
MSSAK 116
3@30 amp
CFN 211
1@15 amp
Part No. 000783, 24-m09-2015