Overview
does not support hot swapping. The six ports are numbered from top to bottom, left to right. Pair ports 1 and
2, 3 and 4, and 5 and 6 to form hardware bypass paired sets.
Figure 14: FPR2K-NM-6X1SX-F, FPR2K-NM-6X10SR-F, FPR2K-NM-6X10LR-F
1
3
5
The 1-G SX /10-G SR/10-G LR network modules have the following insertion loss measurements. Insertion
loss measurements help you to troubleshoot the network by verifying cable installation and performance.
Table 2: 1-G SX Network Module (FPR2K-NM-6X1SX-F)
Insertion loss
Captive screw/handle
Bypass LEDs B1 through B3:
• Green—In standby mode.
• Amber, flashing—Port is in hardware
bypass mode, failure event.
• Amber—Port is in hardware bypass
mode, forced.
Ethernet X/3 (top port)
Ethernet X/4 (bottom port)
Ports 3 and 4 are paired together to form
a hardware bypass pair.
Operating Mode
Normal
Hardware bypass
1-G SX/10-G SR/10-G LR Network Module with Hardware Bypass
6 network activity LEDs
2
• Amber—No connection, or port is not
in use, or no link or network failure.
• Green—Link up, no network activity.
• Green, flashing—Network activity.
Ethernet X/1 (top port)
4
Ethernet X/2 (bottom port)
Ports 1 and 2 are paired together to form a
hardware bypass pair.
6
Ethernet X/5 (top port)
Ethernet X/6 (bottom port)
Ports 5 and 6 are paired together to form a
hardware bypass pair.
Typical
0.9 dB
1.2 dB
Cisco Firepower 2100 Series Hardware Installation Guide
Maximum
1.4 dB
1.7 dB
21