2.1 Examples

Want read data from only Pluto 0.
Use DIP switch configuration.
Easy configuration for read data from one or several Pluto unit with station number 0 – 15.
Want read data from Pluto 0 and 14.
Use DIP switch configuration.
Easy configuration for read data from one or several Pluto unit with station number 0 – 15.
Want read data from only Pluto 24.
Use ABB robotic system configuration.
As soon data from a Pluto above station number 15 then use ABB robotic system
configuration.
Want read data from Pluto 16 and 24.
Use ABB robotic system configuration.
As soon data from a Pluto above station number 15 then use ABB robotic system
configuration.
Want read data from Pluto 5 and 24.
Use ABB robotic system configuration.
As soon data from a Pluto above station number 15 then use ABB robotic system
configuration.
Want read data from Pluto 0 and also send data to Pluto 0.
Use ABB robotic system configuration.
As soon send data to Pluto then use ABB robotic system configuration.
If want to read data from Pluto 0 – 24.
Use ABB robotic system configuration.
There are a need to read data from more then 16 Pluto then use ABB robotic system
configuration and also use two Pluto gateway.
Configure one Pluto gateway to read data from Pluto 0-11.
Configure the other Pluto gateway to read data from Pluto 12-24.
If want to read data from Pluto 0 – 24 and also send data down to the Pluto system.
Use ABB robotic system configuration.
There are a need to read data from more then 16 Pluto then use ABB robotic system
configuration and also use two Pluto gateway.
Configure one gateway to read for example data from Pluto 0-11.
Configure the other gateway to read for example data from Pluto 12-24.
Configure only one of the gateways to handle data sent to the Pluto system.