Enable Data To Pluto; Data To Pluto Timeout; Data To Pluto Cycle Time - ABB Pluto Series Integration Manual

Table of Contents

Advertisement

Pluto 31 add 2147483648
Give the value of 3221225487 (DefValue).

5.8 Enable data to PLUTO

The "plutoNetEnb" command will enable the transmission of output data to the Pluto network from
the gateway. Note the output data from ABB robotic system to gateway will have data for all
package 0 to 3. This configuration will enable the gateway will retransmit the selected output
package part received from ABB robotic system to Pluto network. The value is a bit mask there bit
0 corresponded package 0 and bit 1 to package 1.
Name
plutoNetEnb
Type
plutoGateway
Value
0 – 15
Order
4
Path
6,20 64 24 00 30 10,D1,1
Service
Set_Attribute_Single (0x10)
Bit mask table for "plutoNetEnb" value.
Enable Package
0
1
2
3
To enable output package 0 and 2 add the value 1 and 4 equal 5 (DefValue).

5.9 Data to PLUTO timeout

The "plutoTimeout" command will set a timeout [ms] regarding minimum update time of data from
ABB robotic system to the gateway. It the gateway is not receiving new data within this timeout
from the ABB robotic system the output data sent to the Pluto network will be cleared.
Name
plutoTimeout
Type
plutoGateway
Value
0 – 65535 ms
Order
5
Path
6,20 64 24 00 30 11,C7,2
Service
Set_Attribute_Single (0x10)

5.10 Data to PLUTO Cycle Time

The "plutoCycleTime" command will set a cycle time [ms] regarding how often data to Pluto is send
on the Pluto bus to connected Pluto units. Default time is 100 ms and setting a lower value will
increase the bus traffic on the Pluto bus.
Name
plutoCycleTime
Type
plutoGateway
Value
0 – 255 ms
Order
6
Path
6,20 64 24 00 30 12,D1,1
Service
Set_Attribute_Single (0x10)
Bit
Decimal value
0
1
1
2
2
4
3
8
18
2TLC172011M0205_B

Hide quick links: