Error
Cause
Error
Hardware error
Technical data
Distance measurements:
Measuring accuracy up to 10 m (2 σ)
Power Range Technology™:
Range (use target plate from about 100 m)
Smallest unit displayed
Distance measurement
Minimum/maximum measurement, Conti-
nuous measurement
Area/volume calculation of room data
Addition / subtraction
Indirect measurement using Pythagoras
Trapezium measurement
Tilt measurements:
Tilt sensor:
Accuracy (2 σ)
- to laser beam
- to the housing
Indirect measurement using tilt sensor
(direct horizontal distance)
Angle measurement using tilt sensor
(360°)
General:
Laser class
Laser type
Ø laser point
(at distances)
Autom. laser switch-off
Leica DISTO™ D8 LCA782205a gb
Remedy
Switch on/off the device several
times. If the symbol still appears,
then your instrument is defec-
tive. Please call your dealer for
assistance.
typically: ± 1.0 mm*
0.05 m to 200 m
0.1 mm
- 0.1° / +0.2° **
± 0.1° **
II
635 nm, < 1 mW
6 / 30 / 60 mm
(10 / 50 / 100 m)
after 3 min
17
Autom. instrument switch-off
Display illumination
Multifunctional endpiece
Timer (self-triggering)
Save constant value
Historical storage
BLUETOOTH® 2.0
Range of BLUETOOTH® Cl. 2
Tripod thread (Type: 1/4-20)
Battery life,
Type AA, 2 x 1.5V
Protection against splashes and dust
Dimensions
Weight (with batteries)
Temperature range:
Storage
Operation
* maximum deviation occurs under unfavourable conditions such as bright sunlight or
when measuring to poorly reflecting or very rough surfaces. Measuring accuracy
between 10 m and 30 m may deteriorate to approx. ± 0.025 mm/m, for distances
above 30 m to ± 0.1 mm/m. In long range mode the maximum deviation from a
distance of 30 m increases to +/- 0.15 mm/m.
** applies at room temperature. For the whole operating temperature range the
maximum deviation increases by +/- 0.1°.
Measuring conditions
Measuring range
The range is limited to 200 m.
At night or dusk and if the target is in shadow the measuring range without
target plate is increased. Use a target plate to increase the measurement
range during daylight or if the target has poor reflection properties.
after 6 min
D
GB
F
I
30 values
QD ID B014433
E
10 m
P
up to
NL
5 000 measurements
CN
IP 54, dust-proof,
splash-proof
143.5 x 55 x 30 mm
195 g
-25°C up to +70°C
(-13°F up to +158°F)
-10°C up to +50°C
(14°F up to +122°F)

Appendix