Download Print this page

Operating Instructions - Galvin Specialised Ezy-Wash TF83HJS Product Installation Manualline

Pre-rinse tapware

Advertisement

TF83HJS
5. Secure pre-rinse assembly
Secure Pre-Rinse assembly with the
supplied flanged back nut; ensure the
sealing rubber washer is placed
underneath the Pre-Rinse body flange.
7. Fit hose
Fit hose to the Pre-Rinse riser with a
spanner.
Ensure supplied fiber washer is fitted inside
of hose nut.

OPERATING INSTRUCTIONS

 The isolation or main taps must be turned OFF whilst the unit is not in use so that the unit is not under mains
pressure when unsupervised. Flood damage may occur if a failure occurs whilst the unit is under mains
pressure. (warranty is void in this instance).
 Galvin Specialised recommends the handpiece be removed periodically for servicing by a qualified plumber.
TF83HJP
6. Secure support rod
1. Fasten support rod securely against CP riser.
2.
TF83HJS
8. Test unit
Version 1, 11 July 2017, Page 4 of 5
Tighten compression nut on wall bracket to
secure the support rod. The rod is now rigid.
TF83HJP
Once all fittings have been tightened securely
and the unit has been connected to the mains
water, the unit must be tested for any leaks.

Advertisement

loading

This manual is also suitable for:

Ezy-wash tf83hjp