Download Print this page
Galvin Specialised Ezy-Wash TF83HJS Product Installation Manualline

Galvin Specialised Ezy-Wash TF83HJS Product Installation Manualline

Pre-rinse tapware

Advertisement

Quick Links

Ezy-Wash
®
Pre-Rinse Tapware
PRODUCT CODE:
- TF83HJS
- TF83HJP
SPECIFICATIONS
 Galvin Specialised recommends the installation of strainers and pressure reducing valves prior to installing
the pre-rinse unit to ensure clean consistent water supply. Debris or poor water quality could cause the
trigger to seize or fail to seal.
 This pre-rinse unit has a 6 star WELS rating, the Pot Filler attachments are 0 star to allow fast pot filling.
The hose on these units is not suitable for potable water and should only be used for washing down/
cleaning purposes.
TECHNICAL DATA
Inlet
Outlet
Headworks
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strives to improve their products. Specifications may change without
notice. Higher temperature or pressures could result in premature failure and void the manufacturer's warranty.
TOOLS REQUIRED
 Adjustable spanner
 Hex key
Power drill
Version 1, 11 July 2017, Page 1 of 5
TF83HJS
½" BSP – Male
TF83HJS
Trigger Spray
TF83HJP
Trigger Spray & Pot Filler
TF83HJS
Jumper Valve
TF83HJP
Jumper Valve
Min
100
Max
500
Min
5
Max
65
TF83HJS
3.5
TF83HJP
15
Chrome
TF83HJP

Advertisement

loading

Summary of Contents for Galvin Specialised Ezy-Wash TF83HJS

  • Page 1 TF83HJP SPECIFICATIONS  Galvin Specialised recommends the installation of strainers and pressure reducing valves prior to installing the pre-rinse unit to ensure clean consistent water supply. Debris or poor water quality could cause the trigger to seize or fail to seal.
  • Page 2: Pre-Installation

    Version 1, 11 July 2017, Page 2 of 5 PRE-INSTALLATION Body:  If the mounting holes do not already exist, mark out and drill the holes in the bench, as shown.  This model is a dual inlet unit requiring a hole diameters of 23mm - 26mm, 205mm apart.
  • Page 3: Installation

    Version 1, 11 July 2017, Page 3 of 5 INSTALLATION INSTALLATION COMPLIANCE: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 4: Operating Instructions

     The isolation or main taps must be turned OFF whilst the unit is not in use so that the unit is not under mains pressure when unsupervised. Flood damage may occur if a failure occurs whilst the unit is under mains pressure. (warranty is void in this instance).  Galvin Specialised recommends the handpiece be removed periodically for servicing by a qualified plumber.
  • Page 5: Warranty

    Version 1, 11 July 2017, Page 5 of 5 WARRANTY The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty.