User Interface

Alignment Indication

Installation

LED Status
The Standard IO operation table provides LED status in the RUN mode during
operation. The sensor is always in RUN mode, except when being taught.
Standard IO Operation (Auto PNP/NPN)
Operating Mode Indication
Green
Flashing in (1.4 Hz)
Orange
IO-Link Operation Mode Indication
Green
Orange
The green LED can also serve as a set-up alignment aid, which indicates that a
margin of 1.5, has been reached. The indication means that the sensor is receiving
at least 1.5 times the signal strength back from the target that is required to
trigger an output signal. In general, it is desirable to have a higher margin to help
overcome any deteriorating environmental conditions, for example, dust build-
up on the sensor lens. When aligning the sensor, the preferred performance can
be obtained if this margin indicator is illuminated with the target in place. When
Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015
Green LED
Orange LED
OFF
ON
Flashing (6 Hz)
Unstable light: 0.8 X < margin < 1.5 X
Output short circuit protection active
OFF
Output de-energized
ON
Output energized
OFF
Flashing (1 Hz)
OFF
Output de-energized
ON
Output energized
Installation
Chapter
Power is OFF
Power is ON
Power is OFF
Power is ON
2