  • Page 1 Step by step for KX-UDS/UDT series installation (KX-UDS/UDT series) June 13 , 2017 Ver.1.2 Panasonic Corporation © Panasonic Corporation 2017...
  • Page 2: Revision History

    To add example of how to site survey. UDS124 : 01.002 or later To add taking few minutes before to be able July 3, 2017 Ver. 1.2 to do handover after finishing registration. All versions Add page 47 © Panasonic Corporation 2017...
  • Page 3: System Configuration

    This is called "Handover" and is only possible within the same Air Sync Group. • The system requires one Super Master CS to control the system as a whole. The Air Sync Master CS of Air Sync Group 1 becomes the Super Master CS. © Panasonic Corporation 2017...
  • Page 4: Overview Of Installation Process

    Basic Network Configuration Basic Network Configuration CS Registration CS Registration Tree Survey Configuration Configuration Handset Registration Handset Registration Tree Survey is not required in the case there is only 1 hop to Master from each slave. © Panasonic Corporation 2017...
  • Page 5 Procedure 1. Site Survey 2. Basic Network Configuration 3. CS Registration 4. Tree Survey 5. Configuration 6. PS Registration Appendix © Panasonic Corporation 2017...
  • Page 6 1.3 Example of How to site survey 1.4 Example of How to make site MAP 3. CS Registration 4. Tree Survey ・After confirming the CS coverage area for air synchronization, confirm the speech quality. 5. Configuration 6. PS Registration Appendix © Panasonic Corporation 2017...
  • Page 7 LED turns on Red and Green flashing alternately. Red fast flash > Red and Green flashing alternately [This LED pattern indicates Site Survey master (signal generator) mode.] 2. Put Site Survey Master CS into appropriate position. © Panasonic Corporation 2017...
  • Page 8 IP address) Moderate Red flashing No find site survey signal (Before getting IP address) It takes around a minute to be sync again, if Slave slave CS is not sync with master CS during Red LED status. © Panasonic Corporation 2017...
  • Page 9 4. Confirm whether the LED of Slave CS is slow green flashing. If it is not slow green flashing, move Slave CS around to find a location where its LED turns slow green flashing. Master Slave 5. Repeat steps 3 for all other locations. © Panasonic Corporation 2017...
  • Page 10 (Please refer to “41-003” about explanation with visual information.) After Site Survey, you should exit Site Survey Master mode (press RESET button while power is supplied to CS), turn off all CS used for Site Survey once. © Panasonic Corporation 2017...
  • Page 11 1. Enter “Maintenance mode”. 1. Turn on PS. (See above) 2. Press “MON.” button. 2. Select “CS Area Check”, 3. Press “OK”. MON. MENU and press “OK” twice. Display during CS Area Check on the screen © Panasonic Corporation 2017...
  • Page 12 Even if you confirm the CS Area check using PS, Finally you need to confirm radio signal between Master Master CS and Slave CS by LED status. 3. Place the Master CS where the Slave CS was, and Repeat steps 1 for all other locations. © Panasonic Corporation 2017...
  • Page 13 MAP. When you need to change the CS location, you can confirm the MAP. Example of Site MAP2 (Radio signal condition) (Location1) CS Cover Area CS Area check (Location2) © Panasonic Corporation 2017...
  • Page 14 Press RESET switch again for 1 seconds while 5. Configuration the LED flashes [Green/Red] alternately. (Once CS has been turned off after you set the CS as site survey mode, CS resets automatically after above procedure. 6. PS Registration Appendix © Panasonic Corporation 2017...
  • Page 15 The CSs are assigned IP address by Static or Dynamic (DHCP server). Default setting is DHCP. Notice ・ The IP address of Super Master must be Static setting. ・ In case you set IP address from Web UI and use provisioning, see “Section 5.1.2”. © Panasonic Corporation 2017...
  • Page 16 Password : adminpass 5. After log in, Configure network settings of CS and click [Save]. [Network] → [Basic Network Setting] 6. Log in to the Web user interface again using the newly assigned IP address for the CS. © Panasonic Corporation 2017...
  • Page 17 1. In the [System] tab, select [Air Settings]. [System] → [Air Settings] 2. In CS Class, select “Master”. 3. Click [Save]. ・The CS will restart automatically. ・The CS is now set as the Super Master CS. You may exit Site Survey Mode. © Panasonic Corporation 2017...
  • Page 18 ・ When the IP address of the Super Master CS is unknown, see “Appendix B”. 5. Click [Save]. ・The CS will restart automatically. ・The CS is now set as an Air Sync Master CS. You may exit Site Survey Mode. © Panasonic Corporation 2017...
  • Page 19: Site Survey

    CSs that are not in the Air Sync Group are turned off. 5. Configuration • Repeat CS Registration for each Air Sync Group. • Confirm the MAC address of each CS before registering it. 6. PS Registration Appendix © Panasonic Corporation 2017...
  • Page 20 You cannot register the following CSs: • CSs that are not connected to the network • CSs that cannot receive radio signals from the Air Sync Master CS • Please refer to “41-003” for causes other than the above. © Panasonic Corporation 2017...
  • Page 21 You cannot register the following CSs: • CSs that are not connected to the network • CSs that cannot receive radio signals from the Air Sync Master CS • Please refer to “41-003” for causes other than the above. © Panasonic Corporation 2017...
  • Page 22 3. Select the CS which you want to delete and click to check the box. 4. Click [Delete CS Registration] and Click [OK]. ・ The CS which you select are cleared in “CS Registered List”. Notice: After deleting, the CS which you select reboots automatically. © Panasonic Corporation 2017...
  • Page 23 3. Select an Air Sync Group which you want to add. 4. Select the Number of CS which you want to add. 5. Click [Start CS Registration]. 6. Click [OK]. 7. Then, additional CSs appear in “CS Registered List” and the registration sequence complete automatically. © Panasonic Corporation 2017...
  • Page 24 ・To add a CS at the End of the connecting tree. 6. PS Registration Note The result of the Tree Survey will be shown in Appendix a new pop-up window. Make sure the pop-up blocker is disabled on your browser. © Panasonic Corporation 2017...
  • Page 25 ・ Click [Tree Image] to see a connection diagram of the CSs ・ If “Tree Survey Complete” is not displayed, check the next page. If the Tree Survey will be conducted for 10 or more CSs, use the CS Maintenance Tool instead. © Panasonic Corporation 2017...
  • Page 26 CS. Please refer to “41-006” of technical contents on support site for causes other than the above. When Tree survey uncompleted, you must click [Cancel]. * After clicking [Cancel], all CSs will restart automatically. © Panasonic Corporation 2017...
  • Page 27 1. Click [Apply]. 2. Click [OK]. 3. Click [OK]. ・After clicking OK, all CSs will restart automatically. Notice If there are two or more Air Sync Group, repeat Step1 and 2 for each Air Sync Group. © Panasonic Corporation 2017...
  • Page 28 4. Change “CS Class”, “Primary CS Index” and “Secondary CS Index”. (Please refer to the Web document (The reason for needing Tree Survey)) 5. Click [Apply] and Click [OK]. ・After clicking OK, all CSs will restart automatically. © Panasonic Corporation 2017...
  • Page 29 ・ You cannot add a CS at the end of level 8. ・ After clicking OK, all CSs will restart automatically. Notice When you want to add CSs to the middle of the connection diagram, please conduct the Tree Survey again. © Panasonic Corporation 2017...
  • Page 30 User name: admin Password: adminpass 3. Click [Tree Survey], “Tree Survey Wizard” is displayed, then click [Start]. 4. After “Finish” is displayed, click [Finish] button. ・ If “Execution OK.” is not displayed, check the next page. © Panasonic Corporation 2017...
  • Page 31 2)Set correct CS number of Secondary CS. Please refer to “41-006” of technical contents on support site for causes other than the above. When Tree survey uncompleted, you must click [Cancel]. * After clicking [Cancel], all CSs will restart automatically. © Panasonic Corporation 2017...
  • Page 32 This step is no need if there is only 1 hop to master. 1. Tree Survey Results is displayed. ・Select “Primary” or “Primary + Secondary” and confirm the Tree Structure. 2. Click [Apply]. 3. Click [OK] and click [OK]. ・After clicking OK, all CSs will restart automatically. © Panasonic Corporation 2017...
  • Page 33 5.1 Overview of provisioning information, an extension name, and 5.1.1 Provisioning of process extension number by Web UI. 6. Handset Registration 5.1.2 How to set server URL 5.1.3 Configuration structure 5.1.4 Configuration file for IPEI 5.2 Configuration © Panasonic Corporation 2017...
  • Page 34 DHCP server option 66 and download the configuration file. (Pre-Provisioning) After pre-provisioning, you can set up the CS automatically by downloading the configuration file stored on the provisioning server into the CS. Protocols for Provisioning : HTTP, HTTPS, FTP, TFTP © Panasonic Corporation 2017...
  • Page 35 TFTP server. STEP3 The URL of the server where the configuration file for provisioning is stored is set to the CS. STEP4 STEP4 The CS downloads the configuration file for provisioning from the provisioning server. © Panasonic Corporation 2017...
  • Page 36 Redirection server. STEP2 The URL of the server where the configuration file for provisioning is stored is set to the CS. STEP3 STEP3 The CS downloads the configuration file for provisioning from the provisioning server. © Panasonic Corporation 2017...
  • Page 37 ・ When IP address of the Super Master CS is unknown, see “Appendix B”. 2. In the [Maintenance] tab, select [Provisioning Maintenance]. [Maintenance] → [Provisioning Maintenance] 3. Enter provisioning server URL to “Master File URL”. 4. Click [All Save]. © Panasonic Corporation 2017...
  • Page 38: Configuration File Structure

    … #VoIP Settings: # Setting for PS1 Codec・RTP・Miscellaneous VoIP etc.. # Line Setting #Line Settings: IPEI_PS1=“123456789012” PHONE_NUMBER_PS1_1=“3331231“ SIP settings・PS configuration etc.. SIP_AUTHID_PS1_1=“userid1" SIP_PASS_PS1_1=“userpass1" PHONE_NUMBER_PS1_2=“3331232“ SIP_AUTHID_PS1_2=“userid2" SIP_PASS_PS1_2=“userpass2" # Setting for PS2 … # Setting for PS255 … © Panasonic Corporation 2017...
  • Page 39 Tone Option SIP_AUTHID_PS1_1=“userid1" System Option System Option SIP_PASS_PS1_1=“userpass1" Other Option PHONE_NUMBER_PS1_2=“3331232“ Setting Handset SIP_AUTHID_PS1_2=“userid2" SIP_PASS_PS1_2=“userpass2" # Setting for PS2 … H/S Information Ver.:01.08.000 IPEI: CS Version # Setting for PS255 00398 0115902 Enable CS Web … © Panasonic Corporation 2017...
  • Page 40 5. In Proxy Server Address, enter the IP address of the SIP Proxy server. 6. In Proxy Server Port, enter the port number of the SIP Proxy server that is set to communicate with the CS. 7. Click [All Save]. © Panasonic Corporation 2017...
  • Page 41 This step can be done by provisioning CODEC Preferences Information 1. In the [VoIP] tab, select [VoIP Settings]. [VoIP] → [SIP Settings] 2. In CODEC Preferences, select a codec to use and specify its priority. 3. Click [All Save]. © Panasonic Corporation 2017...
  • Page 42 Procedure 1. Site Survey 2. Basic Network Configuration 3. CS Registration 4. Tree Survey 5. Configuration 6. PS Registration 6.1 PS Registration © Panasonic Corporation 2017...
  • Page 43 4. Press [Line1 SIP Setting] or [Line2 SIP Setting]. 5. Enter the “Phone Number”. (Enter “Authentication ID” and “Authentication Password” If necessary.) 6. Click [All Save] and click [Back]. 7. Repeat 2 to 5 for each PS. © Panasonic Corporation 2017...
  • Page 44 2. Select the PSs to be registered in Available PS, and then click [>]. To select all available PSs, click [>>]. To deselect PS(s), click [<] or [<<]. 3. Click [Next]. 4. Click [OK] to confirm registration. © Panasonic Corporation 2017...
  • Page 45 Performing the registration procedure on multiple PSs at the same time may result in an error. In this case, perform the registration procedure again. • After registering PSs, the Web port will be closed. See “Appendix A” to open the Web port again. © Panasonic Corporation 2017...
  • Page 46 The CS-ID and signal strength of the CS you are connected to and the target CS for Handover is displayed on the PS. When the signal strength is sufficiently strong, the CS-ID is displayed in green. (Please refer to “41-003” about explanation with visual information.) © Panasonic Corporation 2017...
  • Page 47 CS one by one after finishing registration procedure with other various data sent/received between CS1 and each CS. It takes 5 minutes as maximum. This period doesn’t depend on the number of CSs or number of PS registering at the same time. © Panasonic Corporation 2017...
  • Page 48 Appendix A : How to Open the CS Web port Appendix B : How to find out IP address of 6. PS Registration Super Master CS Appendix C : CS’s LED change at the time of Appendix CS Registration © Panasonic Corporation 2017...
  • Page 49: Appendix A : How To Open The Cs Web Port

    ・ You may need to enter a system password to access this menu. 6. Press [NEXT] to display the second screen, select "Enable CS Web", and then press [OK]. 7. When the operation is complete, "CS Web Enabled" is displayed. © Panasonic Corporation 2017...
  • Page 50: Appendix B : How To Find Out Ip Address Of Super Master Cs

    IP address is set to [192.168.0.241]. 3. Log in to http://192.168.0.241/ 4. Input ID and Password for administrator. ID : admin Password : adminpass Log in by WEB Browser ID: admin Pass : adminpass RESET Switch © Panasonic Corporation 2017...
  • Page 51 8. In the [System] tab, select [PS Registration]. 9. Click [Start PS Registration]. 10. Select “1”to be registered in Available PS, and then click [>]. To deselect PS(s), click [<] or [<<]. 11. Click [Next] and click [OK] to confirm registration. © Panasonic Corporation 2017...
  • Page 52 13. Press [Menu] or the [CENTER] navigation key. 14. Select "Setting Handset" and then press [OK]. 15. Press [NEXT]. 16. Select “Other Option" and then press [OK]. 17. Select “MasterCSAddress” and the press [OK]. ・ Display the Master CS IP address. © Panasonic Corporation 2017...
  • Page 53: Appendix C : Cs's Led Change At The Time Of Cs Registration

    Master CS Slave CS Air Sync Master CS Slave CS Super Master CS : Green Slave CS Slave CS Air Sync Master CS : Green Slave CS Slave CS (Inside): Green Slave CS (Outside): Slow red flashing © Panasonic Corporation 2017...