14.2 Resetting selection count to zero
1) Place the programming switch
2) hold down the key
PROG.
3) place the programming switch
4) to start resetting press the key
5) to confirm resetting press the key
i
The procedure described above makes it possible to reset the counts of the single selections (group
1-2-3, milk selections), but not to reset the machine completely (machine life cycle).
S
15.
ignals
1,1 atm
120°C
boiler filling
1,1 atm
120°C
filling timeout
doser alarm
reg. softener
i
If the right keypad of the machine does not work, it may be due to incorrect positioning of the program-
ming switch (set to ON). Make sure that the programming switch is always OFF.
i
If the machine will not work call technical assistance.
(1)
in the OFF position ;
STOP
of the left push button panel for 5 seconds;
in the ON position ;
(1)
;
for 3 seconds.
cause
Boiler filled with water when using the
machine for the first time or when refill-
ing to reach the water level.
Time for filling the boiler with water
longer then expected.
Fault of the volumetric electronic
control .
Lack of water softener regeneration.
solution
Wait for the boiler to be completely filled.
Make sure the mains cock is opened.
Switch off and on again the machine. If
the warning is still on after a few inter-
ventions call the Technical Assistance.
Stop brewing by pressing the dose key.
Call the Technical Assistance.
Carry out the water softener
regeneration. To put off the warning turn
the programming switch on ON and
press simultaneously the 4 display keys
for 5 seconds
DISPLAY - AVANTGARDE
1
espresso gr1
00000000
reset counting ?
press + 3 sec.
data reset
.
23