Fiber Optic Ethernet Ports - Siemens RUGGEDCOM RS900GF Installation Manual

Hide thumbs Also See for RUGGEDCOM RS900GF:
Table of Contents

Advertisement

Chapter 3
Communication Ports
WARNING!
Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded
cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the
RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more
importantly, create a potential shock hazard that can result in serious injury.
LEDs
Each port features an LED that indicates its link/activity state and current speed.
2
1
Figure 10: LED for RJ45 Ports (1 to 8)
1. Link LED    2. Activity LED
Pin-Out
The following is the pin-out description for the RJ45 connectors:
8
Figure 11: RJ45 Port Pin Configuration
Specifications
For further specifications, refer to
Section 3.2

Fiber Optic Ethernet Ports

Optional 1000Base-SX and 1000Base-LX fiber optic Ethernet ports are available for ports 9 and 10 with either
LC (Lucent Connector) and SC (Standard or Subscriber Connector) connectors. Make sure the Transmit (Tx) and
Receive (Rx) connections of each port are properly connected and matched to establish a proper link.
16
2
1
1
Section 4.3, "Copper Ethernet Port
Pin
Name
1
RX+
2
RX-
3
TX+
4
Reserved (Do Not Connect)
5
Reserved (Do Not Connect)
6
TX-
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
Specifications".
RUGGEDCOM RS900GF
Installation Guide
Description
Receive Data+
Receive Data-
Transmit Data+
Transmit Data-
Fiber Optic Ethernet Ports

Advertisement

Table of Contents
loading