Fiber Optic Ethernet Port Specifications; Operating Environment; Mechanical Specifications - Siemens RUGGEDCOM RS900GF Installation Manual

Hide thumbs Also See for RUGGEDCOM RS900GF:
Table of Contents

Advertisement

RUGGEDCOM RS900GF
Installation Guide
Section 4.4

Fiber Optic Ethernet Port Specifications

The following details specifications for all optional fixed fiber optic Ethernet ports that can be ordered with the
RUGGEDCOM RS900GF. For more information about the SFP ports, refer to
Ports".
NOTE
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens Sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages. To convert from average to peak add 3 dBm.
To convert from peak to average, subtract 3 dBm.
• All cabling is duplex type unless otherwise specified.
Connector
Mode
Type
MM
LC
SM
LC
SM
LC
SM
SC
SM
SC
i
Typical.
Section 4.5

Operating Environment

Parameter
Ambient Operating Temperature
Ambient Relative Humidity
Ambient Storage Temperature
Operating Altitude
Section 4.6

Mechanical Specifications

Dimensions
Fiber Optic Ethernet Port Specifications
Cable
i
Tx λ (nm)
Type (μm)
50μ/125
850
9μ/125
1310
9μ/125
1310
9μ/125
1310
9μ/125
1310
Range
-40 to 85 °C
(-40 to 185 °F)
5% to 95%
-40 to 85 °C
(-40 to 185 °F)
0 to 15240 m
(0 to 50000 ft)
Refer to
Chapter 5, Dimension Drawings
Section 3.2, "Fiber Optic Ethernet
Tx min
Tx max
(dBm)
(dBm)
-9.5
-4
-9.5
-3
-5
0
-10
-3
-7
-3
Comments
Measured from a 30 cm (12 in) radius surrounding the center of the
RUGGEDCOM RS900GF enclosure.
Non-condensing
Over temperature range of -40 to 85 °C (-40 to 185 °F)
Technical Specifications
Rx
Rx
Sensitivity
Saturation
(dBm)
(dBm)
-20
0
-22
-3
-22
-3
-22
-3
-24
-3
Chapter 4
Distance
i
(km)
0.5
10
25
10
25
21