Other Approvals; Emc And Environmental Type Tests - Siemens RUGGEDCOM RS900GF Installation Manual

Hide thumbs Also See for RUGGEDCOM RS900GF:
Table of Contents

Advertisement

Chapter 6
Certification
Section 6.1.7

Other Approvals

This device meets the requirements of the following additional standards:
• EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and
Telecommunications Apparatus
Section 6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS900GF has passed the following Electromagnetic Compatibility (EMC) and environmental
tests.
EMC Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
28
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips and Interrupts
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Enclosure Ports
DC Power Ports
Test Levels
± 8 kV
± 15 kV
10 V/m
± 4 kV
± 4 kV
± 4 kV
± 4 kV
± 4 kV Line-to-Earth
± 2 kV Line-to-Line
± 4 kV Line-to-Earth
± 2 kV Line-to-Line
± 4 kV Line-to-Earth
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
40 A/m Continuous
1000 A/m for 1 s
30% for 0.1 s
100% for 0.02 s
100% for 0.05 s
RUGGEDCOM RS900GF
Installation Guide
Severity Levels
4
4
3
4
4
4
4
4
4
4
3
3
3
3
Other Approvals