sys.provisioning-
NUMBER
interval
sys.snmp-enable
BOOLEAN
sys.snmp-
TEXT
community
sys.snmp-
TEXT
contact-name
sys.snmp-device-
TEXT
location
sys.snmp-address
TEXT
sys.recent-call-
BOOLEAN
enabled
sys.ui-mask
NUMBER
Yamaha CS-700 Integrators Reference Guide
1..44640 :
1440 (1 day)
Provisioning interval
in minutes
0 : Disable SNMP
0
1 : Enable SNMP
Read-only community
public
string.
Contact name.
Device location.
IP address or DNS
name.
0 : Disable recent call
1
list
1 : Enable recent call
list
0 : All menus are
0
enabled in the dialer
4 : Do not allow
modifications of call
forwarding
8 : Do not allow
modifications of call
history
16 : Do not allow
modifications of
contacts
32 : Do not allow
modifications of DND
Specify the provisioning
interval for the device, in
minutes..
Enable or disable SNMP
support..
Specifies the SNMP read-
only community string used
for queries from the server
and transmitted traps.
Read-only indicates the
authorization level. The
device does not support
write operations initiated
through SNMP.
Specifies the contact name,
typically the system
administrator. This string is
informational and can
include an email address. It
is not associated with traps.
Specifies the location of the
device for informational
purposes.
Specifies SNMP server
address to which traps will
be sent. Leave blank to
disable traps.
Enables or disable the
Recent Calls list.
Enable or disable menus in
dialer via a bit mask