Advertisement

ColorSource ThruPower
User Manual
1.0
rev A
This product is intended for professional use only.
Read this entire document before using this product.
Copyright © 2015 Electronic Theatre Controls, Inc.
All rights reserved. Product information and specifications subject to change.
Part Number: 7121M1200-1.0.0
Released: 2015-12

Advertisement

Table of Contents
loading

Summary of Contents for ETC ColorSource ThruPower Series

  • Page 1 ColorSource ThruPower User Manual rev A This product is intended for professional use only. Read this entire document before using this product. Copyright © 2015 Electronic Theatre Controls, Inc. All rights reserved. Product information and specifications subject to change. Part Number: 7121M1200-1.0.0 Released: 2015-12...
  • Page 2 ET C ® i s a re g i st e re d t ra d em ar k o f El e c tr o n i c T h ea tr e Co n t ro l s , I n c . i n th e U n i te d S ta te s a n d o t h er c o u n t r i e s .
  • Page 3: Table Of Contents

    Document conventions ........1 Help from ETC Technical Services ......2 Overview .
  • Page 4 Vacuum the interior ....... . 21 Replacement parts ....... . . 22 Troubleshooting .
  • Page 5: Introduction

    RISK OF ELECTRIC SHOCK! This warning statement indicates situations where there is a risk of electric shock. ETC's user documents are designed for printed or electronic use. However, there are many advantages to using the electronic (PDF) versions. In addition to the benefits of a PDF (such as word search, bookmarks, and commenting tools) you can click on headings in the Table of Contents and jump to the desired page.
  • Page 6: Help From Etc Technical Services

    To search more widely, try the ETC website at www.etcconnect.com. If your questions are not sufficiently addressed by these resources, contact ETC Technical Services directly at one of the offices identified below. Emergency service is available from all ETC offices outside of normal business hours.
  • Page 7: Overview

    Overview The ColorSource ThruPower is designed to provide professional quality dimming, packaged for venues that require affordable, professional quality wall mount dimming in low noise environments. The cabinet may be installed with or without other system components making it a cost-effective power solution. 12-circuit models Removable cable entry 12 circuits of dimming/switching...
  • Page 8: 24-Circuit Models

    24-circuit models Removable cable entry 24 circuits of dimming/switching panels at top of enclosure DMX512 native device Passive cooling for quiet operation in low-noise environments Multi-language user interface display including English, Spanish, German, and French User-selectable dimming curves, including Mod Square Law, Linear, Preheat, and Fluorescent Removable cable entry panels at sides of enclosure...
  • Page 9: Product Variants

    Product variants The instructions in this manual apply specifically to the following ColorSource ThruPower models: Installed Weight Channel Model Part Number Breaker Count Dimensions CSTP12 7121A1212 10 A SP CSTP12-ND 7121A1212-ND 10 A ND 36 kgs with packaging 31 kgs without packaging 10 A with RCD CSTP12-RCD 7121A1212-RCD...
  • Page 10: Option Kits

    WARNING: RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all power to the cabinet before working inside could result in serious injury or death. This equipment is intended to be serviced and installed by suitably qualified personnel only. Option kits The following option kits are available for the ColorSource ThruPower.
  • Page 11: Menus And Configuration

    Chapter 1 Menus and configuration User interface The ColorSource ThruPower user interface and menu structure provide you with an easy, intuitive setup with built-in multiple language options. LCD Screen Power LED Power DMX LED Keypad LED indicators Power The power LED has four indication patterns: •...
  • Page 12: Keypad

    Keypad The keypad allows you to easily navigate the menu system. LED or Description Symbol Return to the home menu Move backward one level in the menu Accept a menu choice or store a value Increase a value or scroll through the menu Decrease a value or scroll through the menu Activate the Test menu The LCD is a high-contrast, backlit display, 8 lines high and 20 characters wide.
  • Page 13: Initial Power Up Display

    Initial power up display The first time you apply power to the cabinet, you are asked to choose a language for the operating system. Choose Language English Français Deutsch Espanol ThruPower configuration See “Mode” on Configure the ThruPower operational behaviours through the Mode menu. page 11.
  • Page 14: Menu Structure

    • The vents must not be obstructed. Once the overtemperature condition is corrected, the error should clear. If the error persists, contact ETC Technical Services for assistance. The Home screen displays the following: Bargraph – Shows active dimmer levels. Shows 12 or 24 bars, depending on the ColorSource model.
  • Page 15: Settings Menu

    Settings menu You can open the Settings menu from the Home screen by pressing any button. Through the Settings menu you can open any of three configuration menus or view system version numbers. Settings Output Setup General Settings About Used to set DMX-related parameters. Output Setup Used to set output-related parameters.
  • Page 16 DMX Start "DMX Start" and the start address are displayed if you selected the "Start Address" menu option in the Mode menu. The start address range is 001–512, minus the cabinet output count. Set the DMX start address as follows: ...
  • Page 17 DMX Loss Behavior The DMX Loss Behaviour menu allows you to set the behavior of the dimmers when data communication is lost. DMX Loss Behaviour Mode: Hold Last Look Wait: 0 min 3 sec Fade: 0 min 3 sec M o d e In the "Mode"...
  • Page 18: Output Setup

    Output Setup Output Setup From Dimmer: 1 to 1 The Output Setup menu is used to set circuit- Mode: Dimmer related parameters. Curve: Mod-Square Emergency Threshold From Dimmer The From Dimmer menu allows you to select the dimmers for which you will configure the output.
  • Page 19 The ColorSource ThruPower is capable of dimming or switching multiple load types, including incandescent, low voltage, and 2-wire fluorescent. You can choose from four output curves: 100% 100% 100% Control Input 100% Control Input Mod-Square: The mod-square curve Linear: The linear curve provides a non-linear relationship between provides a linear relationship control level and voltage.
  • Page 20: General Settings

    Emergency The Emergency menu option allows you to configure the ColorSource ThruPower’s emergency contact input. When an active emergency contact is received, all non-emergency dimmers in the cabinet are forced off, while all user-selected emergency dimmers are driven to full. When an emergency contact input is active, the LCD displays a message advising “Emergency Active,”...
  • Page 21 Language The Language menu allows you to select from multiple language options:  Step 1: Press the [Enter] ( ) button. Step 2: Use the [Increase] (+) or [Decrease] (–) button to highlight the language: • English • Français (French) •...
  • Page 22: About

    About Version About Version 1.0.0.0.0.13 Displays the current software version. DimEng 1.0.0.2 DimEng (Dimming Engine) RDM ID 6874:ABCDE00F Serial 4500000123 Displays the current Dimming Engine version. Triac Board 1 Triac Board 2 RDM ID Displays the ID of the current RDM device connected Serial Displays the serial number...
  • Page 23 ColorSource ThruPower System OK DMX Start = 1 L1: OK L2: OK L3: OK V1.0.0.0.0.13 To set groups of dimmers to different levels: Step 1: In the "Dimmer" menu option, all dimmers are selected by default, either "1 thru 12" or "1 thru 24", depending on the ColorSource model. To select a range ...
  • Page 24: Exit The Test

    Step 5: Repeat steps 1 through 4 to set the remaining dimmers. Step 6: This activates the dimmers at the levels you selected. This can be verified on the Home screen, by pressing the [Home] (<<) button. ColorSource ThruPower System OK DMX Start = 1 L1: OK L2: OK L3: OK V1.0.0.0.0.13...
  • Page 25: Appendix A Service And Maintenance

    A ppe n di x A Service and maintenance Help from ETC Technical Services page To contact ETC Service, refer to Maintenance Vacuum the vents Vacuum the dust from the airflow vents regularly. The interval between cleanings is dependent on the amount of dust and other contaminants present in the installation environment.
  • Page 26: Replacement Parts

    Replacement parts The following field-replaceable parts are used in the ColorSource ThruPower. Field replacements are available from ETC or may be purchased at your local electrical supply house. Location Part ETC Part Number Power Input Board, Location F1 Fuse, 2A 250V F 5x20mm...
  • Page 27: Troubleshooting

    • Ensure that the bar graph on the home screen displays the expected levels for the outputs. • If the bar graph shows zero but the output is still on, you may have a failed triac. Consult a qualified service person to have the triac replaced, or contact ETC technical services. Troubleshooting...
  • Page 28 ColorSource ThruPower User Manual...
  • Page 29: Appendix B Menu Flow Chart

    A p pe ndi x B Menu flow chart Home Screen Bar Graph Shows active dimmer levels, as DMX Mode many as 12 or 24, depending ColorSource ThruPower In Start Address mode: on the ColorSource model. DMX Start = xxx System OK In Patched mode: DMX Start = 1...
  • Page 30 ColorSource ThruPower System OK DMX Start = 1 L1: OK L2: OK L3: OK V1.0.0.0.0.13 Press any button on keypad Mode Start Address DMX Start DMX Loss Behaviour Settings Output Setup General Settings About DMX Patch Mode Patched Output: DMX Patch DMX Address: DMX Loss Behaviour DMX Loss Behaviour...
  • Page 31 Output Setup Mode From Dimmer: 1 to 1 Dimmer Mode: Dimmer Relay Curve: Mod-Square TPAuto Emergency Always On Threshold Curve Mod-Square Linear Preheat Fluorescent General Settings Restore Defaults Backlight Auto Language English Are you sure? This Blanking (us): will restore all Restore Defaults settings to factory defaults.
  • Page 32 Service: (DE) techserv-hoki@etcconnect.com   Hong Kong Tel +852 2799 1220 Service: (Asia) service@etcasia.com   Web: www.etcconnect.com Copyright © 2015 ETC. All Rights Reserved.  7121M1200-1.0.0 Rev A Released 2015-12 Product information and specifications subject to change.   ...

Table of Contents