Menu structure

Home screen

Following initial start-up and the selection of a language, the Home screen becomes the
primary display when the ColorSource ThruPower is turned on. From anywhere in the menu
system, you can return to the Home screen at any time by pressing the
The display also returns to the Home screen after 2 minutes of inactivity.
Bargraph
System Status
WARNING:
The Home screen displays the following:
Bargraph – Shows active dimmer levels. Shows 12 or 24 bars, depending on the
ColorSource model.
System Status – Shows one of three conditions:
• System OK – The system is operating normally
• Temperature High – System is in a high-temperature condition
• Emergency Active – Emergency Input is active
DMX Mode – Shows one of two conditions:
• DMX Start = [start address] – System is in Start Address mode
• DMX Patch – System is in Patched mode
Power Status – Shows the status of the incoming three power phases (L1, L2, and L3)
• OK – Output is detected OK
• ERR – The phase is missing or is outside of the acceptable voltage and frequency for
the cabinet
Software Version – The ColorSource ThruPower's current software version
10
ColorSource ThruPower
System OK
DMX Start = 1
L1: OK L2: OK L3: OK
V1.0.0.0.0.13
If an overtemperature condition is displayed, the internal heatsinks have
reached 100° Celsius. Ensure that the exterior of the product is properly
cooled:
• The ambient temperature surrounding the cabinet must not exceed 40°
Celsius.
• The cabinet must be provided adequate airflow.
• The vents must not be obstructed.
Once the overtemperature condition is corrected, the error should clear. If
the error persists, contact ETC Technical Services for assistance.