Changing over the soft-close
mechanism
 Push out soft-close mechanism .
 Remove screws  from the soft-
close mechanism on the right and left
at the bottom of the appliance door.
Caution.
Danger of injury.
Do not move the front part of the
soft-close mechanism in the direc-
tion shown once safety device  has
been removed.
 Remove red safety device  from the
soft-close mechanism.
Changing the door hinging
 Pinch cover  in the middle and re-
move.
 Refit panel  into the cover on the
opposite side.
 Put red safety device  back onto
the soft-close mechanism.