VESPA LX 150 4T Euro 3 Service Station Manual page 67

Table of Contents

Advertisement

Vespa LX 125 - 150 4T Euro 3
5) Once the above operations have been per-
formed, install the battery on the vehicle ensuring
that it is wired up properly.
1 Hold the vertical tube
2 Look at the level
3 The float must be freed
WARNING
- ONCE THE BATTERY HAS BEEN INSTALLED IN THE VE-
HICLE IT IS NECESSARY TO REPLACE THE SHORT TUBE
(WITH CLOSED END) NEAR THE + POSITIVE TERMINAL
WITH THE CORRESPONDING LONG TUBE (WITH OPEN
END), THAT YOU FIND FITTED TO THE VEHICLE, TO EN-
SURE THAT THE GASES THAT FORM CAN ESCAPE
PROPERLY.
Specific tooling
020333Y Single battery charger
020334Y Multiple battery charger
Battery maintenance
The battery is an electrical device which requires careful monitoring and careful maintenance. The
maintenance rules are:
1) Check the level of the electrolyte
The electrolyte level must be checked frequently and must reach the upper level. Only use distilled
water, to restore this level. If water topping is required too often, check the vehicle electrical system:
the battery works overcharged and is subject to quick wear.
2)Load status check
After topping-up the electrolyte level, check its density using an appropriate densitometer (see figure).
When the battery is charged, you should detect a density of 30 to 32 Bé corresponding to a specific
weight of 1.26 to 1.28 at a temperature of no lower than 15° C.
A density reading of less than 20° Bé indicates that the battery is completely flat and it must therefore
be recharged.
If the vehicle is not used for a given time (1 month or more) it will be necessary to periodically recharge
the battery.
The battery runs down completely in the course of three months. If it is necessary to refit the battery in
the vehicle, be careful not to reverse the connections, remembering that the ground wire (black) marked
(-) must be connected to the -negative clamp while the other two red wires marked (+) must be con-
nected to the clamp marked with the +positive sign.
3) Recharging the battery
Remove the battery from the vehicle removing the negative clamp first.
Regular bench charging must be carried out with the specific battery charger, (single) or (multiple),
setting the battery charger selector to the type of battery to be recharged. Connections to the power
supply source must be implemented by connecting the corresponding poles (+ to+ and - to -).
Electrical system
ELE SYS - 67

Hide quick links:

Advertisement

Table of Contents