AC Voltage
•
Single Speed Circulation Pump: 120 VAC, .8
amp – 3.8 LRA, 8 GPM @ 5 PSI
•
Single Speed Drain Pump: 120 VAC, 27 ohms,
.65 amp, ~70 second cycle
•
Main Control: Input 120 VAC, Output 120 VAC,
and Output 5 & 13.5 VDC
•
Tub TCO: 120 VAC, 210°F +/- 10°F Manual Reset
(Models with hidden heater do not have a tub
TCO)
•
Exposed Heater 120 VAC
Wet
Watts
793
Ohms
16.4
Amps
6.6
•
Hidden Heater: 120 VAC, 14.4 ohms 7 watts, ~
8.3 amps. (Located in variable speed pump. If
bad, replace pump assembly.)
•
Hidden Heater TCO's (2): First has auto reset,
200°F +/- 10°F reset at 163°F +/- 10°F. Second is
a one-shot at 349°F +/- 10°F (Located in variable
speed pump. If bad, replace pump assembly.)
Dry
625
+/- 5%
23.2
+/- 5%
5.2
+/- 5%
– 9 –
DC Voltage
•
Main Control: Output 5 & 13.5 VDC
•
UI Control: 5 - 13.5 VDC
•
Inverter: 5 VDC communications with main
control, 85 – 135 VDC normal run, Potential 185
VDC
•
Variable Speed Circulation Pump: 85 – 135
VDC volts to phase windings, 185 VDC Potential,
11.68 ohms phase to phase, 1,600 – 3,500 RPM,
6-10 GPM
•
Variable Speed Drain Pump: 88 ohms phase
to phase, 85 – 135 VDC volts to phase windings,
185 VDC Potential. 2,800 – 3,150 RPM
•
Door Switch: 13.5 VDC
•
Water Valve: 13.5 VDC, 32 ohms, .83 GPM, ~1
minute cycle time
•
UI Control: 13.5 VDC
•
Power Dry Fan: 12-13.5 VDC, 6,000 RPM
•
Variable Speed Dry Fan: 6 VDC 6k RPM and 13.5
VDC – 10k RPM
•
Detergent Cup: 13.5 VDC, 25 ohms
•
Rinse Aid Sensor: 5 VDC to LED, 1 VDC feedback
when full, 4 VDC feedback @ low detect (below
20 ml)
•
Flood Switch: 13.5 VDC, .42 amp
•
Turbidity Sensor: 5 VDC to LED, 10K ohms
(in Turbidity Sensor)
Resistance
20k
11k
5.8k
3.4k
2.1k
1.3k
•
Tub Lighting: Top 12-14 VDC, Side 19-22 VDC
Temperature
50°F
75°F
100°F
125°F
150°F
175°F