Service Mode - GE CDT865SxJ0 Series Technical Service Manual

2016 stainless steel tub dishwasher
Table of Contents

Advertisement

Service Mode

Entering Service Mode
NOTE: Entering Service Mode resets the CSM.
The dishwasher must be in Consumer Error Mode
to enter Service Mode. Entering Service Mode will
reset the CSM, allowing loads to be checked for
what caused the CSM to trip. The control will blink
the Normal LED every few seconds for the number
of times corresponding to the load being tested.
On models PDF820SxJ0xx and PDT825SxJ0xx. The
display will scroll the test corresponding to the
proper test on models CDT835SxJ0xx CDT865SxJ0xx,
PDT845SxJ0xx, PDT846SxJ0xx, PDT855SxJ0xx
,ZDT915SxJ0xx and ZDT975SxJ0xx.
While in Consumer Error Mode
Press and hold Cycle Select pad for 5 seconds.
Press Cycle Select to select or increment each
test.
Press Start, to start and stop each test.
PDF820SxJ0xx and PDT825SxJ0xx
LED
Load to
Timeout / Notes
Blink #
Control
Attempts to empty. Takes
1
Drain Pump
approximately 75 seconds
from normal level.
2
Water Valve level. Takes approximately
1 minute.
Runs for approximately
2 minutes, pressing Start
button will alternate
lower spray arm to mid
Circulation
3
and upper spray systems
Pump
(there will be a one or
eight second pause,
see Pressure Diverter,
Operation).
Turns on heater for a
4
Heater
maximum of 2 minutes.
Turns detergent dispense
Detergent
5
solenoid on for a
Module
maximum of 2 minutes.
6
Fan
Actuates fan for 2 minutes.
Service Mode will exit after 5 minutes of Inactivity.
Exit Service Mode by pressing and holding the Cycle
Select and Start pads for 5 seconds, or by pressing
any other pad.
LCD Display Models Show the Load to Control in
the Display:
CDT835SxJ0xx
PDT855SxJ0xx
CDT865SxJ0xx
ZDT915SxJ0xx
PDT845SxJ0xx
ZDT975SxJ0xx
Load to
Timeout / Notes
Control
Attempts to empty. Takes
Drain Pump
approximately 75 seconds from
normal level.
Water Valve
Takes approximately 1 minute.
Runs for approximately 2 minutes.
Circulation
Pressing the Start button will
Pump
alternate wash zones, see Pressure
Diverter, Operation).
Turns on heater for a maximum of 2
minutes.
Heater
run the circulation pump with the
heater.
Detergent
Turns detergent dispense solenoid
Module
on for a maximum of 2 minutes.
Actuates fan for 2 minutes.
Fan
Monogram models will run in max
speed.
Page 47