3.2 - PNEUMATIC SYSTEM
Pneumatic installation is required if your machine is fitted with the "all or nothing" traverse motion.
- Network pressure: 6 bars
+
1
- Maximum rate
- Flow: 5 liters/minute under 6 bars
COMPRESSED AIR SUPPLY DIAGRAM
TAPPING
_~
____ --TO MACHINE
Fig 3.3
For reference:
Your machine is fitted with a "filter -
pressure~
valve - lubricator" conditionning assembly (if the
"all
or
nothing" traverse motion system
;s
installed)..
Periodic control
You should check the levels in the filter and lubricator elements regularly.
Top up when unpressurized using one of the following lubricants:
TYPE OF OIL
VISCOSITY RANGE
BP ENERGOL HLP1 0
Class ISO VG 10
ESSO Spinesso 10
1803448
SHELL TELLUS C1 0
3-4/4